Off-grid electrics glossary
Plain-English meanings of the terms used across our calculators and guides. Each links to the tool or guide that uses it.
A · B · C · D · E · F · H · I · K · L · M · N · P · R · S · T · V · W
- Absorption
- The second charging stage, where the charger holds the battery at a set voltage while the current tapers off. Lead-acid needs a long absorption; lithium a short one. See the charging voltage calculator.
- AC (alternating current)
- Mains-type power that reverses direction many times a second: 230 V 50 Hz in the UK, Europe and Australia, 120 V 60 Hz in North America. An inverter makes it from a battery.
- AGM
- Absorbent glass mat: a sealed lead-acid battery with the acid held in glass-fibre mats. Maintenance-free, but only about half its capacity is usable. See battery types compared.
- Amp (A)
- The unit of electrical current: how much electricity is flowing. Current sets the cable and fuse size. See watts to amps.
- Amp-hour (Ah)
- Battery capacity: a current of 1 A for 1 hour. A 100 Ah battery could supply 5 A for 20 hours. Multiply by voltage to get watt-hours. See Ah to Wh.
- AWG
- American Wire Gauge: the US cable size system, where a smaller number means a thicker cable. See the AWG to mm² converter.
- BMS (battery management system)
- The electronics inside a lithium battery that protect the cells from over-charge, over-discharge, over-current and charging in the cold, and balance the cells.
- Bulk
- The first charging stage, where the charger delivers its full current until the battery reaches absorption voltage.
- Bus bar
- A solid copper bar that joins many cables at one point, so you don't stack too many lugs on a battery terminal. See 12 V wiring basics.
- C-rate
- Charge or discharge current relative to capacity. 1C on a 100 Ah battery is 100 A; 0.2C is 20 A. See the C-rate calculator.
- Charge controller
- The device between solar panels and battery that controls charging. PWM types are simple; MPPT types harvest more. See the charge controller guide.
- Class T fuse
- A fast fuse with very high breaking capacity (about 20,000 A), used as the main fuse on lithium battery banks.
- DC (direct current)
- Current that flows one way, as from a battery or solar panel. Vans, boats and small off-grid systems run on 12, 24 or 48 V DC.
- DC-DC charger
- A charger that takes power from a vehicle's alternator or starter battery and charges the leisure battery at the right voltage. Essential with smart alternators and lithium. See the DC-DC charger calculator.
- Depth of discharge (DoD)
- How much of a battery's capacity is used. 50% DoD means half emptied. Lead-acid lasts much longer at 50% or less; lithium is happy at 80–90%.
- Diversion (dump) load
- A heater or resistor that takes surplus power from a wind or hydro turbine when the battery is full, so the turbine never runs without a load.
- Efficiency
- The share of energy that comes out compared with what goes in. Inverters are typically 85–94% efficient; charge controllers 95–98%.
- Equalisation
- A deliberate controlled overcharge of flooded lead-acid batteries to mix the electrolyte and balance the cells. Never for lithium, AGM or gel unless the maker says so.
- Float
- The final, lower charging voltage that keeps a full lead-acid battery topped up. Lithium batteries don't need it.
- Fuse
- A deliberate weak link that melts to protect a cable from overheating. Size it for the cable. See the fuse size calculator.
- Hook-up (shore power)
- A mains supply from a campsite or marina post. See the hook-up calculator.
- Inverter
- A device that converts battery DC into mains-type AC. Pure sine wave inverters suit all equipment. See the inverter guide.
- Inverter-charger
- An inverter combined with a mains battery charger and transfer switch, which switches automatically between hook-up and battery power.
- Isc (short-circuit current)
- The current a solar panel gives with its terminals shorted: the most it can deliver. Used to size fuses and controllers.
- kWh (kilowatt-hour)
- 1,000 watt-hours: the unit on electricity bills and home battery ratings. A 1 kW heater running for 1 hour uses 1 kWh.
- LiFePO4
- Lithium iron phosphate: the most common lithium chemistry for vans, boats and homes. Long life, flat voltage and good safety, but can't be charged below 0 °C.
- mm²
- Cable size by cross-sectional area of copper, used in the UK, Europe and Australia. See the DC cable size calculator.
- MPPT
- Maximum power point tracking: a charge controller that runs panels at their best voltage and converts the extra voltage into current. 10–30% more energy than PWM.
- Neutral–earth bond
- The single connection between neutral and earth that lets RCDs work. Each AC supply needs exactly one. See the earthing guide.
- Peak sun hours
- The day's solar energy expressed as hours of full sun (1,000 W/m²). Used to size solar arrays. See the solar output calculator.
- Peukert effect
- Lead-acid batteries deliver less capacity at higher currents. See the Peukert calculator.
- Plug-in solar
- Small solar kits (up to 800 W in Great Britain) that plug into a wall socket and feed power into your home. See the plug-in solar guide.
- Power station
- A portable box with a lithium battery, inverter, charger and sockets. See the power station guide.
- Pure sine wave
- An inverter output that matches mains power. Needed for motors, chargers, medical equipment and most electronics; modified sine wave can cause problems.
- PWM
- Pulse-width modulation: a simple charge controller that connects the panel straight to the battery. Fine for small 12 V panels; wastes energy with higher-voltage panels.
- RCD / GFCI
- A safety device that cuts the supply if current leaks to earth, protecting against electric shock. Called a GFCI in North America.
- Self-consumption
- The share of your solar power you use yourself rather than export. See the solar payback calculator.
- Shunt
- A precise low resistance in the battery negative that lets a monitor measure every amp in and out. See the battery monitoring guide.
- Smart alternator
- A vehicle alternator whose voltage varies to save fuel. It won't charge a leisure battery properly without a DC-DC charger.
- Sodium-ion
- A new battery chemistry using sodium instead of lithium, with excellent cold-weather performance. See the sodium-ion guide.
- State of charge (SoC)
- How full a battery is, as a percentage. See the battery voltage chart.
- State of health (SoH)
- A battery's remaining capacity compared with new. See the battery capacity test calculator.
- Surge (start-up) power
- The brief extra power a motor, compressor or pump takes to start, often 3–7 times its running power. Inverters and generators must cover it.
- Transfer switch
- A switch that connects a house to either the grid or a generator, never both. See the transfer switch guide.
- V2L / V2H / V2G
- Vehicle-to-load, vehicle-to-home and vehicle-to-grid: using an electric car's battery to power appliances, a house or the grid. See the EV home backup guide.
- Vmp / Imp
- A solar panel's voltage and current at its maximum power point under standard test conditions.
- Voc (open-circuit voltage)
- A solar panel's voltage with nothing connected. It rises in cold weather, so strings must be checked against the controller's maximum. See the MPPT string voltage calculator.
- Volt (V)
- The unit of electrical pressure. Higher voltage means less current for the same power.
- Voltage drop
- Voltage lost along a cable because of its resistance. Long, thin 12 V cables lose a lot. See the voltage drop calculator.
- Watt (W)
- The unit of power: volts × amps. A 60 W fridge at 12 V draws 5 A.
- Watt-hour (Wh)
- Energy: 1 W for 1 hour. The best way to compare batteries of different voltages. See the Wh to Ah converter.