Solar charge controllers: PWM vs MPPT, sizing and settings
How PWM and MPPT controllers work, when each makes sense, sizing for current and maximum PV voltage, series and parallel panels, charge settings for lead-acid and lithium, installation and fusing, and troubleshooting.
By Michael Johnson · Updated 17 November 2026 · How we check our guides
The solar charge controller sits between your panels and your battery and decides how much of the sun's energy actually ends up stored. Choosing PWM when you needed MPPT, picking one too small, or leaving it on the wrong battery setting are among the most common reasons a solar system underperforms or kills batteries early. This guide covers how PWM and MPPT work, when each makes sense, sizing for current and voltage, wiring panels in series or parallel, settings for each battery type, and troubleshooting.
1. What a charge controller does
- Stops the battery being overcharged, using a multi-stage charge (bulk, absorption, float).
- Stops the battery discharging back through the panels at night.
- Often runs a "load" output with low-voltage disconnect for small DC loads.
- Reports charge current, battery voltage and daily yield, often by Bluetooth.
2. PWM controllers
- A pulse-width modulation (PWM) controller is essentially a fast switch that connects the panel to the battery and pulses it to hold the right voltage.
- The panel is pulled down to the battery's voltage (12–14.4 V), so a "12 V" panel whose best operating voltage is 18 V wastes the difference: you get panel current × battery voltage.
- Cheap (£10–£40), simple and efficient when the panel's operating voltage is only a little above the battery's.
- Panels must be the same nominal voltage as the battery (12 V panels for a 12 V battery); you can't use series strings or 60/72-cell house panels on a 12 V battery.
3. MPPT controllers
- A maximum power point tracking (MPPT) controller is a DC-DC converter. It runs the panel at the voltage that gives maximum power and converts the extra voltage into extra current for the battery.
- Typical gain over PWM is 10–30%, more in cold weather (panel voltage rises) and with long cable runs.
- Lets you wire panels in series for a higher voltage: thinner, cheaper cables and less loss, and you can use low-cost house panels (60/72-cell, 30–45 V) on a 12, 24 or 48 V battery.
- Costs more (£60–£400+ depending on size); a quality unit is worth it for anything over about 150–200 W.
Example: a 200 W "12 V" panel (Vmp 20 V, Imp 10 A) charging a battery at 13 V gives about 130 W through PWM (10 A × 13 V) but about 190 W through MPPT.
4. PWM or MPPT?
| Situation | Choose |
|---|---|
| Single small 12 V panel (up to about 100–150 W), short cables, tight budget | PWM is fine |
| Anything over about 200 W | MPPT |
| House panels (60/72-cell) or panels in series | MPPT (required) |
| Long cable from panels to battery | MPPT, with panels in series |
| Cold climate or winter use | MPPT (bigger gain when cold) |
| Lithium battery | Either, but it must have a lithium profile; MPPT preferred |
5. Sizing: current and voltage
- Current rating (MPPT): panel watts ÷ battery voltage × 1.25. For example 400 W at 12 V: 400 ÷ 12 × 1.25 ≈ 42 A, so a 40–50 A controller. Many MPPTs can be "overpaneled" and simply limit output, but check the maker's maximum PV input.
- Current rating (PWM): the total short-circuit current (Isc) of the parallel panels × 1.25.
- Maximum PV voltage: the panels' open-circuit voltage (Voc) rises in the cold. The cold-corrected Voc of the series string must stay below the controller's maximum (often 100 V or 150 V), with margin. Use the MPPT string voltage calculator and the solar panel temperature calculator.
- Minimum PV voltage: MPPTs need the panel voltage to be several volts above the battery (often battery + 5 V) to start charging; in hot weather and shade, panel voltage drops.
- Name format: "100/30" usually means 100 V maximum PV input and 30 A charge current.
6. Series, parallel and shading
| Series | Parallel | |
|---|---|---|
| Voltage | Adds up | Stays the same |
| Current | Stays the same | Adds up |
| Cables | Thinner; less loss | Thicker; more loss at low voltage |
| Shading | Shade on one panel drags the string down (bypass diodes help) | Each panel works independently |
| Controller | MPPT only | PWM or MPPT |
| Fusing | No string fuse needed for one string | Fuse each string when three or more are in parallel |
On vans, where roof panels get partial shade, series-parallel (2S2P) or one controller per panel can harvest more. Don't mix panels of very different specifications in the same string.
7. Settings for each battery type
| Battery (12 V) | Absorption | Float | Equalise | Temperature compensation |
|---|---|---|---|---|
| Flooded lead-acid | 14.4–14.8 V | 13.2–13.5 V | Occasionally, 15.5–16 V | Yes |
| AGM | 14.4–14.7 V | 13.5–13.8 V | No (unless the maker allows) | Yes |
| Gel | 14.1–14.4 V | 13.5–13.8 V | No | Yes |
| LiFePO4 | 14.2–14.6 V (short) | 13.4–13.6 V or off | Never | No (but block charging below 0 °C) |
Double for 24 V and multiply by four for 48 V. Always follow your battery maker's figures. See the battery charging voltage calculator.
8. Installation and fusing
- Connect the battery first so the controller detects the system voltage, then the panels. Disconnect in the reverse order.
- Fit a fuse or breaker between controller and battery, close to the battery, rated about 1.25 × the controller's output current.
- Fit a DC isolator (and string fuses where needed) on the panel side.
- Keep the controller close to the battery (short, thick cables) and mount it vertically with space for cooling.
- Fit the battery temperature sensor if the controller has one (for lead-acid), and use a battery voltage sense lead if offered.
- Size cables with the DC cable size calculator.
9. Troubleshooting
| Symptom | Likely cause | Check |
|---|---|---|
| No charging in the morning | PV voltage not yet above battery + start threshold | Normal; wait for more light |
| Low output on a sunny day | Shade, dirty panels, wrong angle, PWM with high-voltage panels, controller at its current limit | Measure PV voltage and current at the controller |
| Battery never reaches full | Absorption voltage or time too low, loads running all day, undersized array | Check settings and daily yield |
| Controller shows error or overvoltage | PV voltage above the maximum in cold weather | Reduce panels in series |
| Lithium battery cuts out when charging | Voltage set too high, or charging below 0 °C | Use the lithium profile |
For a step-by-step method, see the fault-finding guide.
10. Frequently asked questions
Is MPPT better than PWM?
For most systems, yes: an MPPT controller harvests 10–30% more energy and lets you use higher-voltage panels and thinner cables. PWM is fine for a single small 12 V panel on a short cable.
What size charge controller do I need?
For MPPT: panel watts ÷ battery voltage × 1.25. 400 W on a 12 V battery needs about a 40 A controller, and its maximum PV voltage must exceed the panels' cold-weather open-circuit voltage.
Can I use a house solar panel with a 12V battery?
Yes, with an MPPT controller rated for the panel's voltage. A PWM controller would waste most of the energy.
Should I connect the battery or panels first?
Battery first, so the controller detects the system voltage; then the panels. Disconnect panels first.
11. Sources
- Victron Energy, which solar charge controller: PWM or MPPT: victronenergy.com
- Morningstar, grounding in off-grid solar systems: morningstarcorp.com
New to some of the terms? See the glossary. Not sure where to start? Try start here.