Getting low-voltage wiring right
At 12 V, the same power needs about twenty times the current it would at 230 V, so cables must be much thicker and small resistances matter. Two checks decide every DC cable: will it carry the current without overheating, and will the voltage drop stay low enough for the equipment to work properly?
Choosing a cable size
The DC cable size calculator picks the smallest standard cable that passes both checks, in mm² or AWG. To check a cable you already have, use the DC voltage drop calculator. Aim for 3% or less on chargers, inverters and fridges.
Fuses protect the cable
A fuse must be big enough not to blow in normal use and small enough to blow before the cable overheats. The fuse size calculator checks both, and warns if your cable is too thin for the fuse. Fit every fuse as close to the battery as you can.
Converting sizes
Cable sold in the UK and Europe is sized in mm²; US cable uses AWG, where bigger numbers mean thinner wire. The AWG to mm² converter has a full chart. For mains hook-up leads and extension reels, use the AC voltage drop calculator, and have mains work checked by a qualified electrician.