Battery monitoring: shunts, BMS apps and voltage
Three ways to measure state of charge, why voltage misleads with lithium, how shunt monitors work and how to set and synchronise one, what lithium BMS apps can tell you, capacity tests and tracking battery health, and monitoring several batteries.
By Michael Johnson · Updated 17 November 2026 · How we check our guides
"How much battery have I got left?" sounds like a simple question, but a voltmeter often gives the wrong answer, especially with lithium. This guide explains how battery state of charge is measured, how shunt-based monitors work and how to set them up, what lithium battery apps can and can't tell you, how to use voltage charts properly, and how to track battery health over time.
1. Three ways to measure state of charge
| Method | How it works | Accuracy | Best for |
|---|---|---|---|
| Voltage | Reads the battery voltage and compares it with a chart | Fair for lead-acid at rest; poor for lithium mid-range | Quick checks |
| Shunt monitor (coulomb counting) | Measures every amp in and out and counts amp-hours | Good (within a few %) if synchronised regularly | Any system, especially mixed charging sources |
| Lithium BMS | The battery's own electronics count current and track cells | Good if the BMS is decent and synchronised | Lithium batteries with Bluetooth |
2. Voltage: useful but limited
- Voltage only reflects state of charge when the battery has rested (no charge or load) for an hour or more. Under load it reads low; while charging it reads high.
- Lead-acid voltage falls steadily from about 12.7 V (full) to 11.9 V (empty), so a rested reading is a fair guide.
- LiFePO4 sits at about 13.1–13.3 V from roughly 20% to 90%: a 0.1 V change can mean 30% of capacity. Voltage only tells you clearly when it's nearly full or nearly empty.
- Temperature and the battery's age shift the readings.
Use the battery voltage chart for each chemistry.
3. Shunt-based battery monitors
- A shunt is a precise, very low resistance in the battery's main negative cable. The monitor measures the tiny voltage across it to work out current, then adds up amp-hours in and out.
- It shows state of charge (%), current (A), power (W), voltage and time remaining.
- Good monitors (for example Victron SmartShunt/BMV, Renogy, Simarine and others) are accurate to around 1%; cheap Hall-effect clamps are less precise at low currents.
- Everything must go through the shunt except the battery itself: chargers, inverter, DC loads and the chassis link all connect to the "system" side.
4. Setting up a shunt monitor
- Install the shunt in the main negative, battery side to the battery, and every other negative on the system side.
- Connect the monitor's positive sense lead to the battery positive with a small fuse.
- Enter the battery capacity (Ah) and chemistry.
- Set the charged voltage just below your charger's absorption voltage (for example 13.2–13.3 V for lead-acid floats, 14.0–14.1 V for LiFePO4 charging at 14.2–14.4 V), the tail current (about 2–4% of capacity) and the detection time.
- Set the Peukert exponent (about 1.05 for lithium, 1.1–1.3 for lead-acid) and charge efficiency (about 99% for lithium, 85–95% for lead-acid).
- Synchronise by charging to 100%: the monitor resets when it sees the charged voltage and tail current.
- Recharge fully at least every week or two so small errors don't build up.
5. Lithium BMS apps
- Many LiFePO4 batteries have Bluetooth apps that show state of charge, cell voltages, temperature and protection status.
- They're very useful for spotting cell imbalance (cells drifting apart by more than about 0.05–0.1 V when full) and the reason for a shutdown.
- Cheaper BMSs may estimate state of charge poorly at low currents, or not count the current used by small loads. A shunt monitor is still worthwhile for the whole system.
- With several batteries in parallel, each app shows one battery; a single shunt shows the whole bank.
6. Tracking battery health
- Capacity test: from 100%, discharge at a steady, moderate load and record the amp-hours delivered until the cut-off. Compare with the rating every year.
- Lead-acid: watch for falling capacity, fast voltage drop under load, and (for flooded) low or unequal electrolyte. Keep it fully charged: sitting partly charged causes sulphation.
- Lithium: watch cell balance, internal resistance (some apps show it) and capacity. They typically keep 80% capacity for thousands of cycles.
- Record daily use and charge from the monitor's history to size upgrades accurately; the battery cost per cycle calculator helps decide when replacement makes sense.
7. Several batteries and banks
- Batteries in parallel should be the same type, age and capacity, with equal cable lengths to the bus bars, so they share current.
- One shunt on the combined negative measures the whole bank.
- Separate banks (for example starter and house) need their own monitoring; many monitors have a second voltage input for the starter battery.
- See the battery series and parallel calculator.
8. Frequently asked questions
Why does my lithium battery voltage barely change?
LiFePO4 has a very flat voltage curve: it stays around 13.1–13.3 V between about 20% and 90%. Use a shunt monitor or the battery's app for state of charge.
Do I need a battery monitor?
For anything beyond a simple system, yes. A shunt monitor shows exactly what's going in and out, which makes it easy to size solar, spot drains and avoid flattening the battery.
Why does my battery monitor show the wrong percentage?
Usually it hasn't been synchronised (charge to 100%), the capacity or charged-voltage settings are wrong, or some current bypasses the shunt.
How accurate are battery voltage charts?
For lead-acid at rest, within about 10%. For lithium, only near full or empty. Readings under load or while charging are misleading.
9. Sources
- Victron Energy, which solar charge controller: PWM or MPPT (system design notes): victronenergy.com
- BoatUS, the latest on lithium batteries: boatus.com
New to some of the terms? See the glossary. Not sure where to start? Try start here.