Solar DC isolators and string fuses
Why isolation matters, where isolators go, choosing a DC isolator, when string fuses are needed, off-grid systems, isolator fires, surge protection, and labelling.
By Michael Johnson · Updated 19 November 2026 · How we check our guides
Solar panels can't be switched off: whenever light falls on them, they make voltage. That's why every solar system needs a way to isolate the panels safely for maintenance, and why the DC side needs protection matched to how many panels are connected in parallel. This guide explains DC isolators and breakers, where they go, when string fuses are and aren't needed, choosing DC-rated parts, labelling, surge protection, and the faults that cause isolator fires.
1. Why isolation matters
- Panel voltage is present in daylight even when the inverter or controller is off.
- DC arcs are harder to break than AC arcs, because the voltage never passes through zero.
- A means of isolation lets you safely work on the inverter or controller, and lets firefighters and electricians make the system safer.
2. Where isolators go
- Grid-tied systems: a DC isolator between the array and the inverter (often built into the inverter), and an AC isolator between the inverter and the consumer unit. UK installations follow BS 7671 Section 712.
- Off-grid systems: a DC breaker or isolator between the panels and the charge controller, and a fuse or breaker between the controller and the battery.
- Isolators should be easy to reach and clearly labelled.
3. Choosing a DC isolator or breaker
- Its DC voltage rating must exceed the array's maximum open-circuit voltage in the coldest weather. Voc rises as panels get colder; see the panel temperature calculator and the MPPT string voltage calculator.
- Its current rating must exceed the array's maximum current (commonly taken as 1.25 × the short-circuit current Isc).
- Some DC breakers are polarised: wired the wrong way round, they may not break the arc. Follow the marked polarity.
- Outdoor isolators need a suitable IP rating and correctly fitted cable glands.
- Buy from reputable suppliers: counterfeit DC breakers are common online.
4. When string fuses are needed
- When strings are connected in parallel, a fault in one string lets the others push current backwards into it.
- With one or two strings in parallel, the reverse current can't exceed what a panel is designed to survive, so string fuses usually aren't needed.
- With three or more strings in parallel, each string normally needs a fuse (or breaker), rated no higher than the panel datasheet's maximum series fuse rating.
- Use fuses designed for PV (often marked gPV) at the array's DC voltage.
- See the solar series and parallel guide and the datasheet guide.
5. Off-grid systems
- Panel-to-controller breaker: lets you disconnect the panels before working on the controller.
- Controller-to-battery fuse or breaker: protects the cable from the battery's very high fault current.
- Most controllers want the battery connected before the panels, and the panels disconnected before the battery. Check the manual.
- See the charge controller guide and the busbars and DC distribution guide.
6. Isolator fires and how to avoid them
- Rooftop and wall-mounted DC isolators have been linked to fires, usually from water getting in, poor terminations or low-quality parts.
- Avoid putting isolators where they're exposed to driving rain unless designed for it; mount with glands at the bottom and use the correct gland sizes.
- Tighten terminals to the stated torque; loose terminals overheat.
- Many modern inverters include an integrated DC isolator, reducing the need for a separate rooftop switch.
- Check isolators and connectors periodically for discolouration or moisture. See the MC4 connectors guide.
7. Surge protection
- Surge protection devices (SPDs) on the DC and AC sides help protect against lightning-induced surges, particularly for long cable runs and ground-mounted arrays.
- See the lightning and surge protection guide.
8. Labelling
- Label DC isolators, junction boxes and cables to warn that they carry live DC during daylight.
- Show where the isolators are, and how to shut the system down, near the consumer unit and inverter.
- Keep a simple diagram of the system with the paperwork.
9. Frequently asked questions
Do I need a DC isolator for solar panels?
Yes: every system needs a safe means of isolating the panels from the inverter or controller. It may be built into the inverter.
Do I need fuses on solar panel strings?
Usually not with one or two strings in parallel. With three or more, each string normally needs a fuse rated at or below the panel's maximum series fuse rating.
Can I use an AC breaker on the solar DC side?
No. Use breakers and isolators rated for DC at the array's maximum voltage.
10. Sources
- SurgePV, BS 7671 for solar installations: surgepv.com
- SurgePV, solar panel stringing and wiring guide: surgepv.com
- IET Wiring Matters, prosumer electrical installations: theiet.org
- Victron Energy, SmartSolar MPPT installation: victronenergy.com
New to some of the terms? See the glossary. Not sure where to start? Try start here.