Solar panels in series or parallel
Series, parallel and series-parallel, pros and cons, PWM and MPPT controllers, cold weather and maximum voltage, minimum voltage, shading, mixing panels, fusing, cable sizing and example layouts.
By Michael Johnson · Updated 18 November 2026 · How we check our guides
As soon as you have more than one solar panel, you have to decide how to connect them: in series (positive to negative, adding the voltages), in parallel (positives together and negatives together, adding the currents), or a mix of both. The choice affects how much power you get in shade and winter, how thick the cables need to be, which charge controller you can use, and whether the controller is safe on a frosty morning. This guide explains series, parallel and series-parallel wiring, shading, mismatched panels, the cold-weather voltage rise that can damage controllers, fusing, cable sizing, and practical layouts for vans, sheds and homes.
1. Series, parallel and series-parallel
| Connection | Voltage | Current | Example: two 200 W panels (Vmp 20 V, Imp 10 A) |
|---|---|---|---|
| Series | Adds up | Same as one panel | 40 V, 10 A |
| Parallel | Same as one panel | Adds up | 20 V, 20 A |
| Series-parallel (2 strings of 2) | Two panels' worth | Two panels' worth | Four panels: 40 V, 20 A |
Power is the same in theory either way; what changes is voltage, current, and how the array behaves in real conditions. Work out any combination with the solar panel series and parallel calculator.
2. Pros and cons
| Series | Parallel | |
|---|---|---|
| Cable size | Thinner cable (lower current) | Thicker cable needed |
| Long cable runs | Better: lower losses | Worse |
| Low light and winter | Reaches the controller's start voltage sooner | May struggle to start in dull light with low-voltage panels |
| Partial shading | Shade on one panel affects the string (bypass diodes help) | Each panel works more independently |
| Controller | Needs an MPPT controller with a high enough voltage rating | Works with PWM or lower-voltage MPPT |
| Fusing | Usually no string fuses for a single string | Fuses often needed with three or more strings in parallel |
3. PWM vs MPPT controllers
- PWM controllers connect the panels almost directly to the battery, so the panel voltage must be close to the battery's. They suit small 12 V panels in parallel.
- MPPT controllers convert higher panel voltages down to the battery voltage efficiently, so they suit series strings and household-size panels.
- See the charge controller guide and the charge controller size calculator.
4. Cold weather and maximum voltage
- Panel datasheets give Voc at 25 °C (standard test conditions). In cold weather it rises, typically by about 0.3% for every degree below 25 °C (check the "temperature coefficient of Voc" on the datasheet).
- Example: a panel with Voc 45 V and a coefficient of −0.3%/°C at −10 °C: 45 × (1 + 0.003 × 35) ≈ 49.7 V. Three in series would be about 149 V, too close to a 150 V controller's limit.
- Exceeding the controller's maximum PV voltage can damage it, sometimes not straight away: the highest voltage occurs when the battery is full and the controller lets the panels rise towards Voc.
- Use the record low temperature for your area, not the average. In the UK, −10 °C to −15 °C is a sensible design figure in many places; colder on high ground.
- Leave headroom below the controller's rating.
5. Minimum voltage and hot weather
- MPPT controllers need the panel voltage to be several volts above the battery voltage to start charging (Victron suggests at least about 5 V above battery voltage, more for some models).
- In hot weather, panel voltage falls. A single "12 V" panel on a 24 V battery, or a short string on a 48 V battery, may not reach the start voltage.
- Check both limits with the string voltage calculator and the panel temperature calculator.
6. Shading
- Panels contain bypass diodes that let current flow around shaded sections, but a shaded panel in a series string still pulls down the string's output.
- In parallel, a shaded panel mostly just reduces its own output.
- Where shading moves across panels at different times (trees, chimneys, van roof vents), parallel or separate controllers for each orientation often perform better.
- Panels facing different directions should go on separate strings or separate MPPT inputs.
- See the solar panel output calculator.
7. Mixing different panels
- In series, the string current is limited by the weakest panel's current, so panels should have similar current (Imp).
- In parallel, the voltage is set by the lowest-voltage panel, so panels should have similar voltage (Vmp).
- Very different panels are best on separate charge controllers; multiple controllers can charge the same battery.
- Old and new panels of the same model mix reasonably well; small differences cost little.
8. Fusing and isolators
- One or two strings in parallel usually don't need string fuses, because a faulty string can't receive more current than the other string can supply.
- With three or more strings in parallel, fit string fuses (or use a combiner box), rated as the panel maker specifies, because the other strings could push excessive current into a faulty one.
- Fit a DC-rated PV isolator between the array and the controller.
- Use proper MC4 connectors and branch connectors; don't mix brands.
- See the DIY solar kit guide and the off-grid solar system guide.
9. Cable sizing
- Use solar cable (H1Z2Z2-K or similar), sized for current and length.
- Series strings at higher voltage allow thinner cable for the same losses, which matters for long runs from a garden array or roof to a shed.
- Keep voltage drop to a few per cent. See the DC cable size calculator and the voltage drop calculator.
10. Example layouts
| System | Typical layout |
|---|---|
| Campervan, two 175 W panels, 12 V battery | Series if the controller allows (e.g. 100 V MPPT) for better low-light charging; parallel if roof vents shade one panel at a time |
| Shed, one 400 W household panel, 12 V battery | Single panel to a 100 V MPPT; check cold Voc |
| Off-grid home, 12 panels, 48 V battery | Strings of 3–4 panels in series on a 150 V or 250 V MPPT, with several strings in parallel or several MPPTs |
| East and west roof faces | Separate strings on separate MPPT inputs |
11. Frequently asked questions
Is it better to wire solar panels in series or parallel?
Series gives higher voltage, thinner cables and better low-light performance with an MPPT controller. Parallel copes better with uneven shading and works with PWM controllers.
Why does solar panel voltage go up in the cold?
Panel voltage rises as temperature falls, typically about 0.3% per degree below 25 °C. Always check cold-weather Voc against the controller's maximum.
Can I mix different solar panels?
In series, panels need similar current; in parallel, similar voltage. Very different panels are best on separate charge controllers.
12. Sources
- Victron Energy community, effect of Voc on MPPT: victronenergy.com
- Victron Energy, SmartSolar MPPT 100/30 and 100/50 manual: operation: victronenergy.com
- SurgePV, solar panel stringing and wiring guide: surgepv.com
New to some of the terms? See the glossary. Not sure where to start? Try start here.