As a battery system grows beyond a battery and a single inverter, the wiring at the battery end can become a tangle of lugs stacked on terminals. Busbars, fuse holders, battery switches and distribution boxes keep it tidy, safe and easy to work on. Getting the fuse type right is especially important with lithium batteries, which can deliver enormous short-circuit currents. This guide covers how DC distribution works, busbars, choosing fuses (MRBF, MEGA, ANL and Class T), battery switches, the order of components, negative distribution and shunts, sizing, layout and labelling, and common mistakes.

A battery short can release thousands of amps in a fraction of a second, melting tools and causing severe burns or fire. Remove jewellery, use insulated tools, keep a cover on positive busbars, and fit the main fuse as close to the battery as possible.

1. How DC distribution works

A typical system runs: battery positive → main fuse → battery switch → positive busbar → individual fuses → inverter, charge controllers, DC-DC charger and a DC fuse box. On the negative side: battery negative → shunt (battery monitor) → negative busbar → every negative cable.

2. Busbars

3. Choosing fuses

FuseTypical useNotes
Blade fuses (ATO/ATC, Maxi)Small circuits up to about 30 A (Maxi up to about 80 A)In fuse boxes for lights, pumps and sockets
MRBF (terminal fuse)Fuse mounted directly on the battery terminalVery close to the battery; check interrupt rating
MIDI and MEGAMedium to large circuits (about 30–500 A)Bolt-down; common in distributors
ANLLarge circuitsCommon and cheap, but lower interrupting capacity; check suitability with lithium
Class TMain fuse on large lithium banksVery high interrupting capacity and fast acting

4. Battery switches

5. The order of components

Battery, main fuse, switch, shunt and busbars wiring diagramBattery bank+−SwitchMain fusePositive busbarShuntNegative busbar (load side of the shunt)InverterSolar charger12 V fuse boxPositiveNegativeFuse or breaker
Typical layout: main fuse close to the battery positive, then the switch and positive busbar, with a fuse on every circuit leaving it. Only the shunt connects to the battery negative; every other negative goes to the load side of the shunt.

6. Negative side and shunts

7. Small circuits

8. Layout and labelling

9. Common mistakes

10. Frequently asked questions

Do I need a busbar in my battery system?

Once you have more than two or three cables per battery terminal, busbars make the system tidier, safer and easier to maintain.

What fuse should I use for a lithium battery?

One rated for DC at your system voltage, sized to protect the cable, with an interrupting capacity above the battery's short-circuit current. Large lithium banks often use Class T main fuses.

Where should the main battery fuse go?

As close as possible to the battery positive terminal.

11. Sources

  1. Victron Energy, Wiring Unlimited: battery bank wiring: victronenergy.fr
  2. Victron Energy, knowledge article: how to wire an RV battery connection (November 2026): victronenergy.com
  3. Victron Energy community, busbar copper directly on battery terminal: victronenergy.com

New to some of the terms? See the glossary. Not sure where to start? Try start here.