An inverter-charger combines three things in one box: an inverter that makes 230 V (or 120 V) AC from your batteries, a mains battery charger, and an automatic transfer switch that passes shore, grid or generator power straight through to your loads when it's available. It's the heart of most serious off-grid homes, boats and motorhomes, and of many home backup systems. This guide explains how inverter-chargers work, transfer time and UPS-style backup, power assist from batteries when the supply is limited, charging, generator support, sizing, wiring and earthing, and how they compare with a separate inverter and charger.
1. How an inverter-charger works
- Supply present: AC input passes through an internal transfer relay to the AC output. The charger uses spare capacity to charge the battery.
- Supply fails or is disconnected: the relay opens and the inverter powers the output from the battery.
- Supply returns: the unit synchronises with it, then switches back and resumes charging.
- Most are bidirectional: the same power electronics work as inverter or charger.
2. Transfer switch and UPS function
- Good inverter-chargers switch over very quickly. Victron, for example, quotes under 20 milliseconds for its MultiPlus, fast enough that computers and most electronics keep running.
- This makes them work like a large UPS for a home office, freezer, router or medical equipment. See the UPS runtime calculator.
- Some loads (clocks, some smart devices) may still reset; test critical equipment.
3. Input current limit and power assist
- You can set the maximum current drawn from the supply, for example 10 A on a campsite hook-up or 16 A from a small generator. The unit reduces charging to stay within it.
- With "power assist" features (PowerAssist on Victron units), if your loads need more than the supply can give, the inverter adds power from the battery to make up the difference, so the site breaker or generator isn't overloaded.
- This lets you run a kettle or microwave on a weak hook-up, or use a smaller generator.
- See the shore power guide and the hook-up calculator.
4. The charger
- Multi-stage charging (bulk, absorption, float and storage) with settings for lead-acid and lithium batteries.
- Battery temperature sensing adjusts voltages for lead-acid.
- With lithium, use the battery maker's voltages, or closed-loop communication with the BMS. See the BMS guide.
- Charger power is typically rated in amps at battery voltage (for example 35 A at 48 V, about 1.7 kW), so check the supply can provide it plus your loads.
5. Working with a generator
- Set the input current limit to the generator's continuous rating.
- Some units can start a generator automatically when the battery is low or the load is high.
- Inverter generators give a clean supply; some older open-frame generators produce a voltage or frequency the inverter-charger may reject. Adjust the acceptance settings only within the maker's guidance.
- See the generator guide and the generator size calculator.
6. Inverter-charger vs separate units
| Inverter-charger | Separate inverter, charger and changeover | |
|---|---|---|
| Automatic changeover | Built in, fast | Needs a separate switch; may have a gap |
| Power assist | Often available | Not usually |
| Cost | Higher for one box | Can be cheaper for small systems |
| Failure | One unit failing loses both functions | One can fail without the other |
| Best for | Homes, boats, motorhomes, backup systems | Small vans, simple setups |
7. Sizing
- Add up the loads you'll run at the same time, and their start-up surges. See the inverter size calculator and the inverter guide.
- Choose a system voltage to match: 12 V for small systems, 24 V or 48 V for larger ones. See the 12 V, 24 V or 48 V guide.
- Check the continuous watt rating at the temperature where it will be installed; output falls as it gets hot.
- Large units can be paralleled or used in three-phase arrangements.
8. Wiring, earthing and RCDs
- Use the battery cable sizes and fuse ratings from the manual. The DC current is high: a 3 kW inverter on 12 V draws over 250 A.
- Earthing and neutral-earth bonding in inverter mode matter for RCDs to work. Many units have an internal earth relay that bonds neutral to earth when inverting. Follow the manual and local wiring rules. See the earthing guide.
- Fit an RCD on the AC output circuits.
- Mains connections, and any connection to a house's fixed wiring, must be done by a qualified electrician. Never backfeed a house without a proper changeover. See the transfer switch guide.
9. Understanding the ratings
- VA (apparent power) and W (real power) are different: a "3,000 VA" unit might be rated at 2,400 W continuous at 25 °C.
- Peak or surge ratings apply for seconds only.
- Charger current is at battery voltage.
- Transfer switch rating limits how much supply current can pass through.
- Read the datasheet carefully: the large number on the front isn't always continuous watts.
10. Frequently asked questions
What is an inverter-charger?
A single unit that's an inverter, a battery charger and an automatic transfer switch, passing mains or generator power through when available and inverting from the battery when it isn't.
How fast does an inverter-charger switch over in a power cut?
Good units switch in under about 20 milliseconds, fast enough for most computers and electronics.
Can an inverter-charger boost a weak generator?
Many can. With a power assist feature, the inverter adds battery power when loads exceed the set input limit.
11. Sources
- Victron Energy, MultiPlus description (transfer time, PowerControl, charger): victronenergy.com
- Victron Energy, MultiPlus-II inverter/charger datasheet: victronenergy.com
- Current Connected, Victron PowerAssist explained: currentconnected.com
New to some of the terms? See the glossary. Not sure where to start? Try start here.