Home › Guides › Generators

Generators: choosing, sizing and running one safely

Everything about portable, inverter and standby generators: power ratings, sizing for motor start-up surges, power quality for electronics, where to put one, leads and RCDs, fuel storage, noise, emissions rules including California's, maintenance, and the regulations in the UK, USA and Australia.

By Michael Johnson · Updated 16 November 2026 · How we check our guides

Carbon monoxide kills. A small petrol generator gives off enough carbon monoxide to kill in minutes in a closed space. Never run one indoors, in a garage, shed, tent, awning or under a closed porch, even with the door open. Fit CO alarms, and keep the generator well away from every door, window and vent.

1. Types of generator

TypeTypical sizeGood forWatch out for
Inverter generator (petrol or dual-fuel)1–7 kWElectronics, camping, vans, home backup of essentials. Quiet, fuel-efficient at light load, clean powerCosts more per kW; small units struggle with big motor starts
Open-frame (conventional) with AVR3–12 kWPower tools, building sites, whole-house backup through a transfer switch at low costLoud (70–75 dB(A) at 7 m), thirsty at light load, rougher waveform on cheap models
Dual-fuel or tri-fuel2–12 kWRunning on LPG/propane (stores indefinitely) as well as petrol; tri-fuel adds natural gasAbout 5–15% less output on gas
Diesel portable or towable5–30 kWLong runtimes, farms, remote cabins, motorhomesHeavy, noisy, expensive; "wet stacking" if run lightly loaded
Standby (fixed, automatic)8–26 kW home sizesWhole-house backup with automatic start, on mains gas, LPG or dieselInstallation, permits and annual servicing
Cheap two-stroke "suitcase"0.6–1 kWVery occasional light usePoor waveform, noisy, oily fuel mix, short life; avoid for electronics

If what you really need is quiet power for a few devices, a battery may be better. See the portable power station guide.

2. Power ratings explained

3. Sizing for motors and surges

  1. List everything that may run at once and add the running watts.
  2. Find the biggest motor and how much extra it needs to start (starting minus running). Fridges, freezers, pumps and air conditioners typically need 2–7 times their running power for a second or two.
  3. Your generator's running rating must exceed step 1, and its peak rating must exceed step 1 plus step 2.
  4. Aim to keep the steady load at 50–80% of the running rating.

4. Power quality and electronics

5. Where to put it

Where to put a portable generator (plan view) Outdoors, on firm level ground, exhaust pointing away from every opening, with nothing combustible around it HOUSE window door window Garage / shed / carport: never, even with the door open US CPSC: 20 ft (6 m) or more UK / AU: well away from openings; more is safer Generator on level ground dry, ventilated exhaust points AWAY from the house inlet heavy-duty outdoor lead or cable to the inlet Rain cover open-sided canopy made for generators, not a tarp Neighbours' windows too CO drifts with the wind CO alarms inside on every level Spare fuel: well away, in shade, never on the generator
Distance, exhaust direction and shelter matter more than the generator's size. Wind can carry exhaust into your house or a neighbour's.

6. Electrical safety: outlets, RCDs and leads

Extension lead voltage drop

LeadCurrent1.5 mm² / 14 AWG2.5 mm² / 12 AWG4 mm² / 10 AWG
230 V, 25 m10 A5.8 V (2.5%)3.5 V (1.5%)2.2 V (1.0%)
230 V, 50 m10 A11.7 V (5.1%)7.0 V (3.0%)4.4 V (1.9%)
120 V, 50 ft (15 m)15 A3.9 V (3.2%)2.4 V (2.0%)1.5 V (1.3%)
120 V, 100 ft (30 m)15 A7.7 V (6.4%)4.8 V (4.0%)3.0 V (2.5%)

Copper, out and back. Keep drop under about 5%, and under 3% for motors. Check other lengths with the AC voltage drop calculator.

7. Fuel choices and storage

FuelStorage lifeProsCons
Petrol (gasoline)3–6 months; longer with stabiliser; 2+ years for alkylate fuelAvailable everywhere, light generatorsEthanol blends (E10) absorb water and gum carburettors; highly flammable
LPG / propaneIndefinite in a sound cylinderClean burning, no stale fuel, easy starting after storage5–15% less power; cylinders need safe outdoor storage; see the LPG and propane safety guide
Natural gas (piped)Unlimited supply while the gas network runsNo refuelling; ideal for standby setsNetwork may also fail in earthquakes and floods
Diesel6–12 months; longer with treatment and dry tanksEfficient, safer to store (high flash point), long engine lifeDiesel bug and wax in cold; heavy, expensive sets

8. Noise

SourceTypical level
2 kW inverter generator, eco mode50–58 dB(A) at 7 m
3.5 kW inverter generator57–65 dB(A) at 7 m
Open-frame 5–8 kW70–76 dB(A) at 7 m
Enclosed home standby, 20 kW60–68 dB(A) at 7 m in exercise and full load

9. Emissions and clean-air rules

10. Maintenance schedule

WhenTask
Before each useCheck oil level, fuel, air filter, leads; clear debris from cooling vents
First 5–20 hours (new engine)First oil change (running-in period; see manual)
Every 50–100 hours or yearlyOil change, clean or replace air filter, check spark plug
Every 100–300 hoursReplace spark plug, clean spark arrester, check valve clearance (some engines)
MonthlyRun under load for 20–30 minutes; exercise standby sets automatically
Before storageRun the carburettor dry or add stabiliser; change the oil; store dry with the fuel tap off
Diesel setsAvoid long running below about 30–40% load (wet stacking); run at heavy load regularly; drain water from fuel filters

11. Running two generators in parallel

12. Generators at campsites and in vans

13. Rules by country

UKUSAAustralia
Connecting to house wiringBS 7671 Section 551.6: changeover switch fitted by a competent electrician; Part P notification in England and WalesNEC Article 702: listed transfer switch or interlock, under a permitAS/NZS 3000 Section 7.3 and AS/NZS 3010: licensed electrician, changeover switch, certificate of compliance
Generator product standardsUKCA/CE marking; BS EN ISO 8528-13 for portable set safetyUL 2201 (portable generator safety, including CO), PGMA G300 (safety and performance); NEC 445AS/NZS 3010; RCM marking; AS/NZS 3012 for construction sites
Carbon monoxideCO alarms to BS EN 50291; landlord CO alarm rules in England, Scotland and WalesCPSC: 20 ft from home, CO shut-off models; state CO alarm lawsState safety regulators: outdoors only, away from openings
EmissionsStage V NRMM limitsEPA Phase 3; CARB SORE (zero-emission from 2028 model year)Product Emissions Standards Act 2017
NoiseOutdoor equipment noise labels; council nuisance powersLocal ordinances; 36 CFR 2.12 in national parksState EPA noise rules; council and park rules
Fuel storage at home30 L petrol without notificationLocal fire code, often 25 gal gasolineState dangerous-goods limits; AS/NZS 2906 containers

14. Buying checklist

  1. Running watts at least 25% above your steady load, and peak watts covering your biggest motor start.
  2. Inverter type if you'll run electronics, chargers or a boiler, or need quiet running.
  3. The right outlets: 240 V twist-lock (US L14-30) or 16/32 A blue industrial socket (UK, Australia) if you plan an inlet and transfer switch.
  4. CO shut-off (US: UL 2201 or PGMA G300 certified).
  5. Electric start and a low-oil shut-off.
  6. Fuel type you can store safely; consider dual-fuel.
  7. Noise rating at 7 m, and eco or idle mode.
  8. Local dealer support and parts availability.
  9. Correct regional approval marks: UKCA/CE, UL/ETL, RCM.

15. Frequently asked questions

Is an inverter generator worth the extra cost?

For electronics, battery charging, boilers, camping and anywhere noise matters, yes. Inverter generators are quieter, use less fuel at light load and give clean power. For power tools or whole-house backup on a budget, a good open-frame generator with AVR is fine.

Can I run a generator in my garage with the door open?

No. Carbon monoxide builds up in garages and seeps into homes even with the door open. Run it outside, at least 20 feet (6 m) from the house in US guidance, with the exhaust pointing away.

Do I need to earth (ground) my portable generator?

Usually not when you only plug appliances into its own outlets; US NEC 250.34 says so explicitly, and most makers agree. When a generator feeds house wiring, an electrician will set up the earthing as part of the transfer switch installation.

How long can a generator run continuously?

Portable petrol generators run until the tank is empty, typically 4–12 hours, and can be refuelled after cooling down. Check the oil every 8–24 hours of running. Standby sets on mains gas can run for days, with oil checks as the maker specifies.

Will California's rules stop me using my petrol generator?

No. CARB's rules apply to new generator engines sold in California from the 2028 certification model year (possibly later with credits). Existing generators can still be used.

Why does my battery charger reject generator power?

Probably because the generator's frequency or waveform is outside the charger's limits. Use the charger's generator or weak-AC mode, reduce the charge current, or use an inverter generator.

16. Sources

  1. US CPSC, portable generator CO safety and certified standards (2025): cpsc.gov
  2. EC&M, NEC requirements for generators: ecmweb.com
  3. RVIA, CARB regulation on small off-road engines explained: rvia.org
  4. CARB, 2021 amendments to the small off-road engine regulations: arb.ca.gov
  5. Australian Government, Product Emissions Standards Act 2017: legislation.gov.au
  6. Electrical Safety Office Queensland, portable generators (AS/NZS 3010): electricalsafety.qld.gov.au
  7. Energy Safe Victoria, generator safety fact sheet (2026): energysafe.vic.gov.au
  8. Government of South Australia, using generators for back-up power: sa.gov.au
  9. US National Park Service regulations, 36 CFR 2.12 audio disturbances: ecfr.gov
  10. UK legislation, Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001: legislation.gov.uk
  11. UK legislation, Petroleum (Consolidation) Regulations 2014: legislation.gov.uk

General guidance only. Follow your generator manufacturer's instructions, and use a qualified electrician for any connection to fixed wiring.