Home › Guides › Campervan wiring

How to wire a campervan: split charging, solar and hook-up

A complete reference design for a van conversion: a 12 V lithium leisure battery charged by a DC-DC charger from the alternator, by 400 W of roof solar and by campsite hook-up. Every battery positive is fused at the terminal and every cable has its own protection. Checked against BS 7671:2018+A4:2026 Section 721 and BS EN 1648-2, with a US section covering NEC Article 551, NFPA 1192 and the RVIA DC standard.

By Michael Johnson · Updated 12 November 2026 · How we check our guides · Open the wiring diagram full size

Safety and legal note. The 12 V side can be built by a careful DIYer. The 230 V hook-up side is an electrical installation under BS 7671. A competent person should design it or check the design, inspect and test it, and issue an Electrical Installation Certificate (EIC) before first use. Lithium batteries can deliver thousands of amps into a short circuit. Every high-current crimp must be made with the correct tool and die (section 11), because a bad joint can overheat without ever blowing a fuse. Fuse sizes, cable sizes and devices here are a worked example for the stated equipment. Always follow the manuals for the parts you actually buy, and check figures against your copy of the regulations.

1. Which rules apply

StandardWhat it covers in a vanKey points used in this design
BS 7671:2018+A4:2026, Section 721 (caravans and motor caravans)The 230 V installation: inlet, consumer unit, circuits, earthing and bonding, notices, the hook-up leadInlet to BS EN 60309-2, IP44 or better, no higher than 1.8 m above the ground. Main isolator breaking all live conductors. 30 mA RCD breaking all live conductors. Overcurrent devices on every final circuit breaking line and neutral. Flexible or stranded cable, minimum 1.5 mm². Protective bonding of accessible structural metalwork, minimum 4 mm² (Reg 721.411.3.1.2). Instruction notice near the inlet (Figure 721).
BS 7671 Amendment 4 (published 15 April 2026, in force since 15 October 2026), new Chapter 57Stationary secondary batteries and battery power conversion equipment, such as inverters, inverter/chargers and mains chargersDC isolators rated for DC (an AC switch doing a DC job is not acceptable). A battery is treated as a source, not a load, and protective devices must suit current flowing both ways where it can (Regs 551.7.1, 530.3.201). The right RCD type upstream of conversion equipment (see RCD type). Battery-presence notices (570.6.8.201) and "WARNING – Isolate both AC and DC sides before servicing" on conversion equipment (570.6.8.203). The article we relied on notes that whether Chapter 57 strictly covers a van leisure battery is open to interpretation, so this design uses it as the benchmark.
BS 7671 Section 712 (solar PV), as amendedPV arraysDC isolation between array and controller. Any DC fuses or breakers rated for at least the array's maximum open-circuit voltage, UOC MAX (Reg 712.533.101(b)). PV conductors not earthed unless the maker says so. Frames bonded.
BS EN 1648-2 (12 V ELV installations in motor caravans)The 12 V habitation systemOvercurrent protection in positive conductors. Battery secured in a protected compartment with terminals marked + and −. Ventilation for vented batteries (minimum 80 mm² low-level vent). Voltage-drop limits; this design aims for 3% or less from battery to appliance.
Equipment manuals (Victron and similar)Fuse sizes, cable sizes, terminal torques, remote-on wiringWhere a manual is stricter than the general rule, follow the manual.

DVLA reclassification as a motor caravan and the MOT don't inspect the habitation electrics. Insurers and buyers do increasingly ask for an EIC for the 230 V side, so keep it with the van's paperwork.

2. The reference system

This is a typical medium/long-wheelbase panel van build. The numbers carry through every table below. If your parts or cable lengths differ, re-run the checks with the calculators in section 14.

PartExample usedNotes
Leisure battery12.8 V 200 Ah LiFePO4 with internal BMS (one battery, or two 100 Ah in parallel)Combined BMS continuous rating of 200 A or more, so it can supply the optional inverter. Check the BMS surge rating too.
Split chargeVictron Orion-Tr Smart 12/12-30 non-isolated DC-DC charger (30 A)Works with smart (Euro 6) alternators when switched by an ignition or D+ signal. Limits alternator load.
Solar2 × 200 W panels in series (about 48 V open-circuit) into a Victron SmartSolar MPPT 100/30Cold-weather open-circuit voltage stays well below the controller's 100 V limit.
Hook-up16 A blue inlet → consumer unit → 30 A mains charger + 230 V socketsA charger on the mains keeps things simple. An inverter/charger is covered in section 9.
DistributionMain fuse → DC isolator → positive busbar with a fuse for each circuit. Negative busbar after a battery-monitor shunt.Every source and every load has a fuse on its positive cable.
Optional inverter1200 W pure sine wave inverter feeding its own socketNot connected to the hook-up circuits.

3. Wiring diagram

Van electrics – reference wiring diagram 12 V LiFePO4 · DC-DC split charge 400 W solar · 16 A hook-up ENGINE BAY / CAB ROOF 230 V AC – BS 7671 SECTION 721 PV panel 200 W Voc ≈ 24 V PV panel 200 W Voc ≈ 24 V series roof gland C3 6 mm² PV cable (H1Z2Z2-K) frame bond PV DC isolator 2-pole, DC-PV rated Solar MPPT 100/30 (30 A) B− → F4 40 A MEGA/MIDI C4 10 mm² DC-DC charger 12/12-30 non-isolated F3 60 A MEGA/MIDI C2 16 mm² B− (common −) Alternator (smart / Euro 6) Starter battery vehicle 12 V F1 60 A MRBF ≤150 mm C1 25 mm² ≈5 m run body earth Ignition-switched live / D+ F2 2 A H pin EHU inlet 16 A BS EN 60309-2, IP44 2.5 mm² 3-core flex Consumer unit Main isolator – double pole RCD 30 mA Type A – double pole MCB1 B10 double pole – sockets MCB2 B6 double pole – charger Earth bar 1.5 mm² flex Mains charger 12 V 30 A F5 40 A MEGA/MIDI C5 10 mm² B− → 2.5 mm² 230 V sockets on RCD Bonding 4 mm² to body / chassis metalwork POSITIVE BUSBAR (e.g. Lynx Distributor / MEGA busbar) F6 50 A MEGA/MIDI C8 16 mm² 12 V fuse box blade fuses Final circuits (example): • Fridge – 15 A fuse, 4 mm² • Diesel heater – 20 A fuse, 4 mm² • Water pump – 10 A fuse, 4 mm² • Lights – 7.5 A fuse, 2.5 mm² • USB / 12 V sockets – 15 A fuse, 6 mm² • Roof fan – 7.5 A fuse, 2.5 mm² F7 150 A MEGA C7 35 mm² Inverter 1200 W OPTIONAL Inverter-only socket not linked to EHU Main DC isolator S1 ≥ 250 A DC rated C6 50 mm² F10 200 A Class T – only with 2 batteries F8 200 A Class T, ≤150 mm F9 200 A Class T Leisure battery 1 LiFePO4 12.8 V 200 Ah internal BMS Leisure battery 2 OPTIONAL, same model each battery has its own fuse on its positive Shunt battery monitor NEGATIVE BUSBAR B− (load side of shunt – all negatives land here) C9 25 mm² link to vehicle body earth point (needed for the non-isolated DC-DC common negative) Key 12 V positive 12 V negative 230 V line (brown) 230 V neutral (blue) Protective earth / bonding Optional item Fuse Cn = cable ref. (see schedule) B− = to negative busbar
Single-line diagram of the reference system. F = fuse, C = cable reference. Both are listed in the schedule in section 5. Dashed boxes are optional.

4. Fusing every battery positive

A fuse protects the cable, so it has to sit where the fault current comes from: the battery end. Any battery in the van can feed a short circuit, and that includes the vehicle's starter battery. So:

"Maxi fuse or similar": which fuse where

Fuse typeInterrupt rating (AIC)RangeUse it for
Class T20,000 A (at up to 125–160 V DC)Up to 400 A+Main lithium battery fuse (F8, F9). This is the safest choice for large LiFePO4 banks.
MRBF terminal fuse (Blue Sea or similar)10,000 A at 14 V DC30–300 ABattery-terminal fusing at 12 V, including F1 on the starter battery. It mounts in a terminal fuse block, not loose on the post. It's also acceptable as a 12 V lithium main fuse.
MEGA / ANL in a holderLower (around 2,000 A for MEGA; check the maker's data)40–500 ACircuit fuses on the busbar (F3–F7), once their interrupt rating has been checked against the battery's fault current (see below).
MIDILower; check the maker's data30–200 ABranch circuits on the busbar.
Maxi blade1,000 A at 32 V DC (Littelfuse data)20–80 ASmall 20–80 A branch circuits, only where its interrupt rating is at least the fault current available at that point. Not recommended directly on a lithium battery terminal, because 1,000 A interrupt is too low for its possible fault current.

So yes: there's a fuse on the positive side of every battery. On the battery terminals, use Class T or MRBF rather than Maxi, because their interrupt rating matches what a lithium or starter battery can deliver.

Check the busbar fuses too. A short on the busbar side can still be fed by the battery's full fault current, and MEGA, MIDI and Maxi fuses have much lower interrupt ratings than Class T or MRBF. Don't assume the main fuse will always clear the fault first: an upstream fuse only reliably protects a smaller one (backup protection) where the maker has tested and documented that combination. Get the battery's prospective short-circuit current from its maker, and check each busbar fuse's interrupt rating at 14 V DC or more. If any is lower, use a higher-rated fuse type (MRBF or Class T), a fuse system with a stated rating high enough, or a documented tested combination.

5. Protection and cable schedule

Rule for every line: load current × 1.25 ≤ fuse rating ≤ cable current rating. The largest cables (C6, C7) need 105 °C-rated cable (tri-rated or welding flex), run singly rather than bundled, to carry their fuse rating. Voltage drops are at copper resistance at 20 °C for the stated one-way lengths. Measure your own runs.

RefLocationProtectsDeviceRatingCableLength / currentVolt drop
F1Starter battery +, ≤150 mm (the positive post; fit nothing to the negative post if it carries an IBS sensor)C1 DC-DC feedMRBF in terminal block60 AC1 25 mm²5 m / 38 A input0.26 V (2.0%)
F2Ignition / D+ sourceRemote signal wireBlade fuse (in-line)2 A0.75–1 mm²signal only–
F3BusbarC2 DC-DC outputMEGA / MIDI60 AC2 16 mm²1 m / 30 A0.06 V (0.5%)
–PV DC isolatorIsolation of array2-pole DC-PV switchCurrent ≥ 1.25 × Isc (≈15 A; a 32 A part is fine). Voltage ≥ cold Voc (use ≥ 100 V DC)C3 6 mm² PV (H1Z2Z2-K)6 m / 11.5 A0.40 V (1.1% of 37 V)
F4BusbarC4 MPPT outputMEGA / MIDI40 AC4 10 mm²1 m / 30 A0.10 V (0.8%)
F5BusbarC5 mains charger outputMEGA / MIDI40 AC5 10 mm²1.5 m / 30 A0.16 V (1.2%)
F6BusbarC8 feed to 12 V fuse boxMEGA / MIDI50 AC8 16 mm²2 m / 40 A max0.17 V (1.3%)
F7BusbarC7 inverter (optional)MEGA150 AC7 35 mm², 105 °C1.5 m / 115 A0.17 V (1.3%)
F8Leisure battery 1 +, ≤150 mmC6 main cable (one battery); battery 1 lead (two batteries)Class T (or MRBF)200 AC6 50 mm², 105 °C1 m / 150 A peak0.10 V (0.8%)
F9Leisure battery 2 +, ≤150 mm (if fitted)Its own cable to the junctionClass T (or MRBF)200 A50 mm², equal length to battery 1––
F10After the battery junction (only with two batteries)C6 and S1Class T200 AC6 50 mm², 105 °C––
S1After F8/F9Main isolationDC battery isolator switch≥ 250 A continuous, DC rated50 mm²––
C9Negative busbar → body earth pointCommon negative return for the DC-DC chargerNo fuse (negative)–25 mm² (same as C1)< 1 m–

12 V final circuits (from the fuse box)

CircuitTypical currentFuseCableOne-way lengthDrop incl. feed
Compressor fridge6 A15 A (or as the fridge manual says)4 mm²4 m2.5%
Diesel heater10 A at start-up20 A (or as the manual says)4 mm²3 m2.9%
Water pump7 A10 A4 mm²4 m2.7%
LED lighting4 A7.5 A2.5 mm²4 m2.5%
USB / 12 V sockets10 A15 A6 mm²4 m2.6%
Roof fan4 A7.5 A2.5 mm²3 m2.1%

Total drop = fuse-box feed (0.11 V at a typical 25 A) + the branch run, as a percentage of 12.8 V. At the full 40 A feed current the worst circuit (the heater) reaches about 3.4%, so use larger cable if you often run everything at once. Every final circuit's fuse is at or below the conservative bundled current rating of its cable, so bundling these runs in a loom is fine.

6. Split charging with a DC-DC charger

7. Solar

8. 230 V hook-up (shoreline)

Inlet and incoming cable

Consumer unit

RCD type

Earthing, bonding and wiring

Hook-up lead

Notices and labels

9. Adding an inverter

10. Installation practice

11. Crimping: the joint is part of the protection

Read this before you make a single high-current connection. A fuse only protects against too much current. It does nothing about a bad joint. A poorly crimped lug on a battery, inverter or DC-DC cable can carry normal current and never blow a fuse, while it heats up quietly behind a panel. Badly made terminations are one of the most common causes of fires in van and boat electrical systems. The fuse schedule in this guide is only safe if every crimp is made properly.

Why it matters: the numbers

Heat in a joint = current² × resistance. A poor crimp with just 1 milliohm of extra resistance gives off:

CableCurrentHeat in a 1 mΩ bad joint
Fridge circuit, 4 mm²6 A0.04 W (harmless)
DC-DC feed C1, 25 mm²38 A1.4 W
Inverter cable C7, 35 mm²115 A13 W
Main battery cable C6, 50 mm²150 A22.5 W, as much as a soldering iron, inside a lug

The heat oxidises the copper, the resistance rises, so it runs hotter still. On high-current cables a bad crimp gets worse over time, and the vibration of a moving van speeds that up. That's why the large cables need the most care.

Use the correct tool for the job

Cable sizeTerminalCorrect toolDon't use
0.5–6 mm² (final circuits)Pre-insulated crimps (red 0.5–1.5, blue 1.5–2.5, yellow 4–6 mm²) or uninsulated terminals sized for the cableRatchet crimper with dies matched to the terminal colour or type. It won't release until the crimp is complete.Cheap "plier" crimpers with a stamped jaw. Pliers. Squashing it with a vice.
Fine-strand flex in screw terminals (fuse box, consumer unit, chargers)Bootlace ferrules sized to the cableFerrule ratchet crimper (square or trapezoidal profile)Tinning the end with solder. It creeps under the screw and works loose.
10–120 mm² (battery, busbar, charger and inverter cables)Tinned copper tube lugs matched to both the cable size and the stud size (for example 50 mm² × M8)Hydraulic crimper with a hexagonal die marked for that cable size, or a long-handled mechanical lug crimper made for that size rangeHammer/anvil crimpers. Mismatched dies ("close enough"). Lugs for a bigger cable with the gap packed out. Copper pipe cut and squashed.

Making a good high-current crimp, step by step

  1. Match everything: cable cross-section = lug barrel size = die size. Choose lugs made for fine-strand (flexible) cable. They have a larger barrel than lugs for solid-core building wire.
  2. Cut square with proper cable cutters, not a hacksaw that frays strands.
  3. Strip to the barrel depth. All strands must go into the barrel, with none bent back or cut off to make it fit. The copper should just show in the inspection hole and the insulation should butt up to the barrel.
  4. Crimp with the die marked for that size. On long barrels, do two crimps working from the palm end towards the cable. Never crimp over the inspection hole area of a lug designed with one.
  5. Inspect: an even, symmetrical hex shape with no cracks in the barrel, no flash squeezed out of the die and no loose strands.
  6. Pull test: a firm hand pull must not move the lug at all. If it moves, cut it off and start again. Never re-crimp a bad one.
  7. Seal: adhesive-lined (dual-wall) heat-shrink over the barrel and onto the insulation, red for positive and black for negative. It keeps moisture out and supports the cable.
  8. Bolt up correctly: lug flat against the busbar or terminal, with nothing (no washers) between the lug and the contact face. Put the washer and spring washer or nyloc nut on top. Torque to the device maker's figure and mark with torque paint so you can see later if it has moved.

Solder and other shortcuts

Check every joint once the system is running

12. Testing and commissioning checklist

12 V side (before connecting the battery)

  1. Every fuse is fitted at the rating in the schedule, with labels matching.
  2. Continuity of every positive and negative run. No short between busbars (measure resistance with the battery disconnected).
  3. Every crimp inspected and pull-tested, and every lug and busbar stud torqued and marked (see section 11).
  4. Connect the battery with the isolator OFF. Check voltage at the busbar side. Switch on one circuit at a time.
  5. Program chargers for LiFePO4 (absorption and float voltages from the battery maker), and set the DC-DC charger's engine detection.
  6. Run the engine and confirm the DC-DC charger starts, delivers its current and stops with the ignition off. Check the voltage drop on C1 under load.
  7. Check solar charging. Use a clamp meter to confirm each load's current is under its fuse rating.
  8. Under heavy load, measure the millivolt drop across each high-current joint, and check for warm lugs with a thermal camera or by touch after 30–60 minutes at full load. Remake any joint that stands out.

230 V side (competent person, BS 7671 Part 6)

  1. Visual inspection: inlet height and IP rating, notices, segregation, cable support.
  2. Continuity of protective conductors and the bonding conductor to the chassis.
  3. Insulation resistance (≥ 1 MΩ at 500 V DC). Disconnect sensitive electronics first.
  4. Polarity at every socket and device.
  5. RCD operation test at its rated residual current IΔn (30 mA, must trip within 300 ms) and the test button.
  6. Earth fault loop impedance on a known supply.
  7. Issue an Electrical Installation Certificate. Fit the next-inspection label.

13. Parts list (example)

ItemQtySpecification
LiFePO4 battery1 (or 2)12.8 V 200 Ah (or 2 × 100 Ah), BMS ≥ 200 A continuous, low-temperature charge protection
DC-DC charger1Victron Orion-Tr Smart 12/12-30 non-isolated (or equivalent 30 A unit)
Solar charge controller1Victron SmartSolar MPPT 100/30
Solar panels2200 W, Voc ≈ 24 V each, with roof brackets and gland
PV isolator12-pole DC PV isolator, ≥ 32 A, ≥ 100 V DC
Mains charger112 V 30 A LiFePO4-capable (e.g. Victron Blue Smart IP22 12/30)
Main fuse(s)1 (or 3)Class T 200 A with holder (or MRBF 200 A with terminal block). With two batteries: one per battery plus F10 after the junction.
Starter battery fuse1MRBF 60 A with terminal fuse block
Battery isolator1DC rated, ≥ 250 A continuous
Busbars1 setPositive fused busbar (e.g. Lynx Distributor or MEGA busbar, 4–6 ways) and negative busbar
Circuit fuses–60 A, 40 A, 40 A, 50 A (MEGA or MIDI); 150 A MEGA if the inverter is fitted
Battery monitor1Shunt-based (e.g. Victron SmartShunt 500 A)
12 V fuse box16–12 way blade fuse box with negative bus
Hook-up inlet116 A 2P+E BS EN 60309-2, IP44, recessed with flap
Consumer unit1Caravan type: DP isolator, 30 mA Type A RCD, DP MCBs B10 + B6 (or DP RCBOs)
Cable–50, 35, 25, 16, 10, 6, 4, 2.5 mm² tri-rated red/black. 6 mm² H1Z2Z2-K solar. 2.5 and 1.5 mm² 3-core flex. 4 mm² green/yellow bonding.
Crimping tools–Hydraulic lug crimper with hex dies for 10–70 mm² (or have the large cables made up by a supplier). Ratchet crimper for insulated terminals. Ratchet ferrule crimper. Proper cable cutters. Torque wrench.
Sundries–Tinned lugs, heat-shrink, grommets, conduit, P-clips, labels, the Figure 721 notice, the Amendment 4 battery notice

14. Check your own numbers

Use these OffGridVolts calculators to adapt the design to your van:

15. Building the same van in the USA

The 12 V design (batteries, DC-DC charger, solar, busbar and fuse layout) carries over almost unchanged to a US build. The shore power side is completely different: 120 V 60 Hz, NEMA connectors, and a different approach to earthing ("grounding"). This section lists what changes and which rules apply.

The legal position in the US. Federal law doesn't set an electrical standard that a DIY van conversion must pass. RVIA certification is a manufacturer programme open only to member facilities. It isn't available to individual builders and isn't a legal requirement. State DMVs that reclassify a van as a motorhome generally inspect features (bed, cooking, water), not the wiring. Some lenders, insurers and RV parks do ask about certification or an inspection. The practical route for a DIY build is to follow the same standards the factories use (below), keep photos and diagrams, and have a licensed electrician review and test the 120 V side. Third-party programmes such as NOAH offer an inspection for custom builds.

Which US rules apply

StandardCoversNotes
NFPA 70 (NEC), Article 551: recreational vehicles. The current edition is 2026; 2023 is still widely adopted.120 V / 240 V AC wiring in the RV: inlet and power cord, panelboard, branch circuits, GFCI, grounding and bonding, generators and inverters, factory testsThe AC rules in this section come from Article 551.
NFPA 1192: Standard on Recreational Vehicles (2026 edition)Whole-vehicle standard: fire and life safety, LP gas, plumbing. It points to the NEC for AC and the RVIA standard for DC.Used by RVIA for certified manufacturers. Mandatory enforcement of the 2026 RVIA standards set began 1 September 2026.
ANSI/RVIA DC Voltage Standard (2025 edition; replaced the ANSI/RVIA LV "Low Voltage" standard)DC systems up to 60 V nominal: batteries, fuses, conductors, routing, splicesThe DC figures quoted below are from LV-2020, the edition we could read. Check the 2025 edition if you need certified compliance. The 2025 edition requires lithium batteries to be listed to UL 1973 or UL 2054.
ABYC E-11 (boats)AC and DC on boatsNot an RV standard, but its fuse-placement rules and ampacity tables for large 105 °C cables are widely used in US van builds. We use them below for cables bigger than the RVIA table covers.
UL 458Inverters, converters and chargers for RVs and boatsArticle 551 requires inverters, converters and transfer switches to be listed for RV use. In practice that means UL 458.

12 V side: what's different

TopicUS rule (ANSI/RVIA LV-2020 unless stated)This design
Fuse locationOvercurrent device within 18 in (457 mm) of where the power source connects to the vehicle circuits, and accessible. ABYC E-11 is stricter: 7 in at the battery.≤150 mm (6 in) at every battery positive. This meets both.
Fuse vs cableThe fuse must not exceed the conductor ampacity in the standard's tables. Fuses and breakers must be DC rated at or above the system voltage, and breakers must be trip-free.Same principle. US sizes are in the table below.
Cable typeStranded copper only, to SAE J1127 (battery cable) or J1128 (primary wire), insulation rated at least 90 °C. Use 125 °C in the engine bay and within 10 in of the exhaust.Use SAE J1127/J1128 cable (SGX/TXL/GXL or marine tinned cable).
Battery chassis groundBattery ground to chassis at least 8 AWG copper, and the same size as the power lead if that is bigger. Converter enclosures are bonded to the frame with 8 AWG.C9 becomes 2 AWG, to match C1.
Separation from 120 VAt least a ½ in (12.7 mm) gap between DC and 120/240 V wiring, or a barrier.Keep the two systems in separate looms and conduit.
SupportSecure conductors at least every 4½ ft (1.4 m). Leave strain relief where parts move, and at least 4 in of free conductor after the last support.Our 300 mm spacing for heavy cables is well inside this. Keep it: big cables in a moving van need it.
Ground returns and hardwareNegative returns must be identifiable (colour or marking). Ground hardware must be plated, on clean metal or with serrated washers.Black negatives. Use the body earth point as in the main design.
Joints and crimpsConnectors must match the conductor size and type. Each splice must pass a 1-minute pull test (e.g. 30 lb for 14 AWG, 40 lb for 10 AWG, 50 lb for 6 AWG). Solder splices must be mechanically secured first. No more than 4 terminals on one stud.Matches the crimping section. Pull-test every joint, and keep stacks to 4 lugs or fewer per stud.
BatteriesSecured and protected. Vented (flooded) batteries need a vapour-resistant box vented to outside, with openings of at least 1.7 in² within 2 in of the top and bottom. Lithium must be listed and installed per its listing.LiFePO4 inside, clamped. Choose one listed to UL 1973 or UL 2054.
SolarSolar is a recognised DC source. Its circuits need no fuse if the cable can carry the largest current available. The RVIA DC standard covers systems up to 60 V nominal.Two panels in series ≈ 48 V Voc (≈53 V cold). Keep the array below 60 V, or larger arrays move into NEC Article 690 PV territory.

US cable and fuse schedule

Each metric cable was replaced by the nearest AWG size that is at least as large, so voltage drops are the same or better than in section 5. Small cables are checked against the RVIA Table 1 ampacities. Battery cables above 2 AWG are checked against ABYC E-11's 105 °C single-conductor ratings outside an engine space (2 AWG 210 A, 1/0 285 A).

RefCircuitFuseUK cableUS cableUS cable rating
F1 / C1Starter battery → DC-DC60 A MRBF25 mm²2 AWG (33.6 mm²)100 A (RVIA)
F3 / C2DC-DC → busbar60 A16 mm²4 AWG (21.2 mm²)75 A (RVIA)
C3PV array → MPPTnone (one string)6 mm² PV10 AWG PV wire (UL 4703)> Isc ≈ 11.5 A
F4 / C4MPPT → busbar40 A10 mm²6 AWG (13.3 mm²)55 A (RVIA)
F5 / C5Converter/charger → busbar40 A10 mm²6 AWG55 A (RVIA)
F6 / C8Busbar → 12 V fuse panel50 A16 mm²4 AWG75 A (RVIA)
F7 / C7Busbar → inverter150 A35 mm²1/0 AWG (53.5 mm²), 105 °C285 A (ABYC)
F8–F10 / C6Battery → isolator → busbar200 A Class T50 mm²1/0 AWG, 105 °C285 A (ABYC)
C9Negative busbar → chassis–25 mm²2 AWG (≥ 8 AWG and ≥ C1)–
–Fridge / heater / pump15 / 20 / 10 A4 mm²10 AWG30 A (RVIA)
–Lights / roof fan7.5 A2.5 mm²12 AWG20 A (RVIA)
–USB / 12 V sockets15 A6 mm²8 AWG40 A (RVIA)

120 V shore power: the US design

USA version – 120 V shore power side (NEC Article 551) 12 V side as main diagram, with AWG cable sizes from the US schedule Shore inlet 30 A NEMA TT-30 flanged, 125 V label: DO NOT EXCEED CIRCUIT RATING (30 A) road (driver) side, within 15 ft of rear Loss-of-ground device (GMI) NEC 2023/2026 10 AWG Cu RV panelboard (dead-front) 30 A main breaker 20 A breaker – GFCI outlets 15 A breaker – converter/charger Neutral bar ISOLATED from case Ground bar bonded to case no neutral–ground bond in the van GFCI receptacle(s) 20 A circuit, 12 AWG Converter / charger listed for RV use to 12 V busbar via 40 A fuse 8 AWG Cu bond to frame (converter) 8 AWG Cu chassis bonding conductor Inverter/charger OPTIONAL listed to UL 458, internal transfer switch + ground relay (bond only when inverting) Dashed = optional. GFCI required for receptacles outside, in a bathroom, or within 6 ft of a sink – in a van, simplest to protect them all. Have a licensed electrician review and test (NEC 551.60: dielectric, bonding continuity, polarity, GFCI).
US shore power side. The 12 V side is as in the main diagram, using the AWG sizes above.

US testing (NEC 551.60)

  1. Dielectric strength test on the 120 V wiring with switches closed: 900 V AC or 1,280 V DC for 1 minute, or 1,080 V AC or 1,530 V DC for 1 second. Do this before the DC is connected and with electronics disconnected. This is a job for an electrician with the right tester.
  2. Continuity of the bonding of all exposed metal and the chassis.
  3. Polarity check of every receptacle and device.
  4. Operational test of every GFCI and appliance, and of the loss-of-ground device if fitted.
  5. Then complete the 12 V checklist and crimp checks exactly as in sections 11 and 12.

16. Sources

  1. IET – Electrical installations in caravan/camping parks, caravans and motor caravans
  2. IET Wiring Matters – The impact of Amendment 4:2026
  3. Electrical Safety First – BS 7671 Amendment 4 pocket guide
  4. Tiny Build Electrics – BS 7671 Amendment 4: campervan, motorhome and cabin changes
  5. Tiny Build Electrics – Which RCD do you need for a campervan?
  6. Caravan and Motorhome Club – Hooking up to the mains
  7. EN 1648-2:2018 – Leisure accommodation vehicles, 12 V DC extra-low-voltage installations, Part 2: motor caravans (catalogue summary)
  8. Victron – Orion-Tr Smart non-isolated manual: installation, fuses and cable sizes
  9. Victron – Wiring Unlimited: DC wiring
  10. Victron – SmartSolar MPPT 100/30 and 100/50 manual: installation (battery fuse, connection order, PV earthing)
  11. Blue Sea Systems – MRBF terminal fuse specifications (interrupt rating)
  12. Littelfuse – MAXI 32 V fuse datasheet (interrupt rating 1,000 A)
  13. Blue Sea Systems – DC circuit protection (ABYC E-11 fuse location)
  14. Just Kampers Insurance – DVLA campervan conversion reclassification
  15. NEC Article 551 – Recreational vehicles (text summary)
  16. ANSI/RVIA LV-2020 – Standard for Low Voltage Systems in Conversion and Recreational Vehicles
  17. Lithionics – 2026 RVIA standards (NFPA 1192 2026, ANSI/RVIA DC 2025, NEC 2026; UL 1973/2054)
  18. RVIA – Grounding monitor interrupters on RVs
  19. The Van Guide – RVIA certification for van conversions
  20. Blue Sea Systems – ABYC conductor ampacity tables
  21. Victron Community – MultiPlus ground relay
  22. RV electrical code overview – NEC and UL 458

This guide is for a typical build, not a substitute for a site-specific design. OffGridVolts accepts no liability for installations based on it. Have the 230 V installation inspected, tested and certified by a competent electrician.

New to some of the terms? See the glossary. Not sure where to start? Try start here.