Connecting batteries in series and parallel
Series and parallel, wiring a parallel bank, wiring in series, fusing, mixing batteries, lithium banks, balancing series strings, and how many batteries.
By Michael Johnson · Updated 19 November 2026 · How we check our guides
Few off-grid systems use a single battery for long. You may want more capacity (batteries in parallel), a higher system voltage (batteries in series), or both. Done well, a battery bank behaves like one big battery; done badly, some batteries work harder than others, wear out early, or a fault in one damages the rest. This guide explains series and parallel connections, wiring a bank so the batteries share the load evenly, fusing, mixing old and new or different batteries, lithium banks with their own BMS, balancing series strings, and how many batteries to connect.
1. Series and parallel
| Connection | Voltage | Capacity (Ah) | Example with 12 V 100 Ah batteries |
|---|---|---|---|
| Parallel (+ to +, − to −) | Stays the same | Adds up | Two batteries: 12 V 200 Ah (2.56 kWh for LiFePO₄) |
| Series (+ to −) | Adds up | Stays the same | Two batteries: 24 V 100 Ah |
| Series-parallel | Both | Both | Four batteries: 24 V 200 Ah |
The stored energy (Wh) is the same either way. Higher voltage means lower current for the same power, so thinner cables and smaller losses. See the 12, 24 or 48 V guide and the battery bank size calculator.
2. Wiring a parallel bank
- Problem: if the main cables connect to one end of the bank, the battery nearest the connection does most of the work, because the links add resistance for the others.
- Diagonal connection: take the main positive from one end of the bank and the main negative from the other, so the current path through each battery is similar.
- Busbar method (best): run a cable of equal length from each battery to a positive busbar and a negative busbar, then take the main cables from the busbars. See the busbars guide.
- Use the same cable size and type for every battery link, and keep lengths equal.
3. Wiring in series
- Connect the positive of one battery to the negative of the next. The bank's terminals are the free negative at one end and free positive at the other.
- Every battery in a series string carries the same current; any weaker battery is pushed harder and can be over-discharged or overcharged.
- Label the bank voltage clearly: a 48 V bank gives a much bigger shock risk than 12 V.
4. Fusing
- With two or more batteries in parallel, a short circuit in one battery or cable can draw current from all the others. Fuse each battery (or each series string) close to its positive terminal.
- Fit a main fuse between the bank and the loads as well.
- Use fuses rated for DC and the bank's short-circuit current. See the fuse size calculator.
5. Mixing batteries
| Mix | Advice |
|---|---|
| Old and new of the same model | Avoid; the old battery drags the new one down. If you must, only in parallel and only with small age differences |
| Different capacities, same chemistry | Avoid in series; possible in parallel but they won't share load evenly |
| Lead-acid and lithium | Don't connect directly together; they need different charging voltages. Use a DC-DC charger between separate banks |
| Different lithium brands | Avoid; BMS behaviour and voltages differ |
6. Lithium banks
- Many 12 V lithium batteries have their own BMS. Check the maker's limits: some allow parallel only, others allow a set number in series.
- Charge each battery fully before connecting them together, so they start at the same voltage.
- If one BMS disconnects, the others carry the full load; size them so that's safe, or use batteries that communicate.
- Larger systems often use a single 48 V rack battery or several 48 V batteries with communication to the inverter. See the BMS guide.
7. Balancing series strings
- In a series string, small differences between batteries grow over time: one ends up fuller than another.
- A battery balancer, or batteries whose BMSs communicate, keeps them equal.
- Check individual battery voltages at rest periodically with a multimeter.
8. How many batteries?
- Fewer, larger batteries are better than many small ones: fewer connections and less imbalance.
- Many makers limit the number of batteries in parallel; follow their figures.
- If you need a lot of capacity, a higher system voltage reduces the number of parallel strings.
9. Frequently asked questions
How do I wire batteries in parallel properly?
Use identical batteries and equal-length cables, and either take the main positive and negative from opposite ends of the bank or connect each battery to busbars.
Can I mix an old and new battery?
It's best not to. The older battery limits the new one and can shorten its life.
Can I connect lithium and lead-acid batteries together?
Not directly. They need different charging voltages. Keep them as separate banks, linked by a DC-DC charger if needed.
10. Sources
- Victron Energy, Wiring Unlimited: battery bank wiring: victronenergy.fr
- Victron Energy community, diagonal battery wiring: victronenergy.com
- Victron Energy community, which battery cabling to prefer: victronenergy.com
New to some of the terms? See the glossary. Not sure where to start? Try start here.