Home › Guides › Soft starters

Soft starters for air conditioners and motors

Why motors need a big starting current, how soft starters work, which loads benefit, types, alternatives such as inverter appliances, choosing and fitting, and limits.

By Michael Johnson · Updated 18 November 2026 · How we check our guides

Motors draw a huge burst of current for a fraction of a second when they start: often several times their running current. That's why a 1,500 W air conditioner can trip a 3,000 W inverter or stall a 2,000 W generator. A soft starter reduces that inrush, letting you run air conditioners, compressors and pumps from smaller generators, inverters and campsite hook-ups. This guide explains starting current, how soft starters work, which loads they suit, alternatives such as inverter-driven appliances, how to choose and fit one, and the limits.

Before buying a soft starter: check whether the appliance is already "inverter" type (variable speed). Inverter air conditioners, fridges and heat pumps ramp up gently on their own and don't need one.

1. Why motors need a big starting current

2. How a soft starter works

3. Which loads benefit

LoadBenefit
Fixed-speed air conditioners (RV rooftop units, window units)High: often lets a 2 kW generator start them
Single-phase compressors and workshop toolsUseful with special motor soft starters
Well and borehole pumpsPumps with variable-speed drives already start softly; otherwise specialist soft starters exist
Fridges and freezersUsually small enough for a good inverter; inverter-type compressors don't need one
Inverter air conditioners and heat pumpsNot needed

4. Types of soft starter

5. Alternatives

6. Choosing and fitting

7. Limits and cautions

8. Frequently asked questions

What does a soft starter do?

It ramps up a motor's start so the surge current is much lower, letting smaller generators and inverters start air conditioners and compressors.

Will a soft starter let me run an air conditioner on a 2 kW generator?

Often, for smaller fixed-speed units, if the running power is within the generator's continuous rating. Check the maker's guidance.

Do inverter air conditioners need a soft starter?

No. Inverter (variable-speed) units already start gently.

9. Sources

  1. RV PRO, Micro-Air EasyStart lets small generators start A/Cs: rv-pro.com
  2. Techno RV, RV soft starters for AC units: technorv.com
  3. The RV Geeks, soft start for RV AC: thervgeeks.com

New to some of the terms? See the glossary. Not sure where to start? Try start here.