Soft starters for air conditioners and motors
Why motors need a big starting current, how soft starters work, which loads benefit, types, alternatives such as inverter appliances, choosing and fitting, and limits.
By Michael Johnson · Updated 18 November 2026 · How we check our guides
Motors draw a huge burst of current for a fraction of a second when they start: often several times their running current. That's why a 1,500 W air conditioner can trip a 3,000 W inverter or stall a 2,000 W generator. A soft starter reduces that inrush, letting you run air conditioners, compressors and pumps from smaller generators, inverters and campsite hook-ups. This guide explains starting current, how soft starters work, which loads they suit, alternatives such as inverter-driven appliances, how to choose and fit one, and the limits.
1. Why motors need a big starting current
- A stationary motor has very low resistance until it spins up; the surge (locked rotor amps, LRA) can be several times the running current.
- Compressors in air conditioners and fridges start against pressure in the system, making it worse.
- Inverters have a short-term surge rating, and generators can only supply so much before the voltage collapses.
- See the inverter size calculator and the generator size calculator.
2. How a soft starter works
- Electronic soft starters ramp up the voltage or control the motor's start winding over a fraction of a second, so the current rises gradually.
- Learning types adjust to the particular compressor over several starts.
- Manufacturers of RV air-conditioner soft starters claim reductions in starting current of 60–75%; actual results vary by unit.
- They're different from hard-start capacitor kits, which give a motor more starting torque but don't reduce current much.
3. Which loads benefit
| Load | Benefit |
|---|---|
| Fixed-speed air conditioners (RV rooftop units, window units) | High: often lets a 2 kW generator start them |
| Single-phase compressors and workshop tools | Useful with special motor soft starters |
| Well and borehole pumps | Pumps with variable-speed drives already start softly; otherwise specialist soft starters exist |
| Fridges and freezers | Usually small enough for a good inverter; inverter-type compressors don't need one |
| Inverter air conditioners and heat pumps | Not needed |
4. Types of soft starter
- Air conditioner soft starters: wired into the compressor circuit of single-phase AC units. Common in RVs and boats.
- Industrial motor soft starters: for three-phase motors and larger pumps.
- Variable-frequency drives (VFDs): give soft starting plus speed control; widely used on pumps.
- Plug-in inrush limiters: limit the surge of some loads, but aren't suitable for every motor.
5. Alternatives
- Buy inverter-type appliances: inverter air conditioners, fridges and freezers start gently and use less energy.
- Choose a larger inverter with a high surge rating (low-frequency transformer inverters handle surges well).
- Use an inverter-charger with power assist to supplement a weak supply. See the inverter-charger guide.
- Don't start several motors at once: see the essential loads guide.
6. Choosing and fitting
- Choose a soft starter designed for the type and size of the motor (for air conditioners, by BTU or tonnage rating).
- Installation usually involves opening the appliance and wiring into the compressor circuit. This is mains electrical work: have it done by a competent person, and check the effect on the appliance's warranty.
- Run the appliance through the soft starter's learning starts on a strong supply before relying on a small generator.
- Check the result with a clamp meter that captures inrush current. See the multimeter guide.
7. Limits and cautions
- A soft starter reduces starting current, not running power: the generator or inverter must still cover the running load.
- Battery-powered air conditioning uses a lot of energy. Use the air conditioner battery calculator.
- Use soft starters that are certified for the voltage and frequency in your country.
8. Frequently asked questions
What does a soft starter do?
It ramps up a motor's start so the surge current is much lower, letting smaller generators and inverters start air conditioners and compressors.
Will a soft starter let me run an air conditioner on a 2 kW generator?
Often, for smaller fixed-speed units, if the running power is within the generator's continuous rating. Check the maker's guidance.
Do inverter air conditioners need a soft starter?
No. Inverter (variable-speed) units already start gently.