Home › Guides › Grid-tied solar and batteries

Grid-tied solar and home batteries: sizing, export, backup and rules

How home solar and batteries work alongside the grid: inverter types, sizing for your bills, whether a battery pays, backup in a power cut, export payments, time-of-use tariffs, plug-in solar, and the connection rules, standards and incentives in the UK, USA and Australia in 2026.

By Michael Johnson · Updated 17 November 2026 · How we check our guides

Most solar in the UK, USA and Australia is grid-tied: the panels and battery work alongside the mains supply rather than replacing it. This guide covers how these systems work, how to size panels and batteries for your bills rather than for independence, what you're paid for exports, how backup in a power cut really works, and the connection rules, standards and incentives in each country as they stand in late 2026.

Grid-connected systems must be installed by qualified people. Connecting an inverter to your house wiring and the network is notifiable or licensed work in all three countries, and the network operator must be told. The one exception is the new plug-in solar category in Great Britain (up to 800 W, see section 9). Everything else here is to help you plan, compare quotes and ask the right questions.

1. How a grid-tied system works

Grid-tied solar with a battery and backup circuit Hybrid inverter: panels charge the battery; the grid fills gaps and takes exports. In a power cut, only backed-up circuits stay on, isolated from the grid. Solar panels 4–6 kWp on the roof Roof isolator / RSD DC switch (US: rapid shutdown) Hybrid inverter MPPT + battery charger + grid-tie inverter Home battery 5–15 kWh LiFePO4 BMS + DC isolator DC (battery) Consumer unit main switchboard AC isolator + RCD/RCBO AC out (grid-tied) Backup / EPS circuits fridge, lights, boiler, router (essential loads) backup output Export meter smart / net meter (SEG, net billing, FiT) Grid DNO / utility / DNSP network import / export Anti-islanding: on grid loss the inverter must stop exporting (G98/G99, IEEE 1547/UL 1741, AS/NZS 4777.2). Backup circuits are fed only through the inverter's own isolating transfer relay.
A typical hybrid system: one inverter handles the panels, battery and grid, with an optional backup circuit.

During the day, the panels make DC electricity. The inverter turns it into AC at grid voltage and frequency and feeds it into your consumer unit (switchboard). Your home uses that power first. If the panels make more than you're using, the surplus either charges a battery or flows out through the meter to the grid. At night or on dull days, you draw from the battery and then from the grid as usual.

The grid acts as an infinitely large, imperfect battery: it always takes your surplus and always fills the gap, but it usually pays far less for exported power than it charges for imported power. That price gap is what drives most decisions in this guide.

Anti-islanding. A grid-tied inverter must stop exporting within a fraction of a second if the grid fails, so it can't feed power into lines that workers think are dead. This is why an ordinary grid-tied system goes off in a power cut, even on a sunny day. Backup needs extra hardware (section 5). For heating water with spare solar, see the solar diverter guide.

2. Inverter types

TypeHow it worksGood forWatch out for
String inverterPanels wired in series strings to one central inverterSimple, unshaded roofs; lowest cost per wattShade on one panel pulls down the whole string unless optimisers are fitted
String + optimisersA small DC converter behind each panelPartly shaded or multi-direction roofs; panel-level monitoringMore electronics on the roof
MicroinvertersA small inverter behind each panel (or pair)Complex roofs, small arrays, easy expansion; AC on the roof (meets US rapid-shutdown rules)Higher cost; batteries must be AC-coupled
Hybrid inverterPanels, battery and grid all on one inverterNew installs with a battery now or later; most efficient battery charging from solarBattery must be compatible with that inverter brand
AC-coupled batteryA battery with its own inverter, added to an existing systemRetrofitting a battery without touching the existing solarSlightly lower round-trip efficiency (two conversions)

3. Sizing the panels

Off-grid systems are sized for the worst month. Grid-tied systems are sized for the best return, which usually means filling the roof you have, within the connection limits in section 8.

LocationTypical yield per kWp per year4 kWp system6 kWp system
Scotland, northern England750–850 kWh3,000–3,400 kWh4,500–5,100 kWh
Southern England900–1,050 kWh3,600–4,200 kWh5,400–6,300 kWh
US north-east / Pacific north-west1,100–1,300 kWh4,400–5,200 kWh6,600–7,800 kWh
US south-west, California1,500–1,750 kWh6,000–7,000 kWh9,000–10,500 kWh
Melbourne, Hobart1,200–1,350 kWh4,800–5,400 kWh7,200–8,100 kWh
Sydney, Perth, Brisbane, Adelaide1,400–1,600 kWh5,600–6,400 kWh8,400–9,600 kWh

Figures are for a well-oriented, unshaded roof. East–west roofs give about 10–20% less in total but spread generation across the day, which suits self-consumption. Work out your own figure with the solar panel output calculator and how many panels fit with the roof fit calculator.

Self-consumption is what saves money

Every kWh you use yourself saves the full import price. Every kWh you export earns the (much lower) export rate. Without a battery, a typical home uses 25–40% of its solar directly; the rest is exported. A battery, a hot water diverter, an EV charger or a heat pump running in the day can raise that to 60–80%.

Annual saving ≈ (self-used kWh × import price) + (exported kWh × export price) Simple payback (years) = installed cost ÷ annual saving

4. Is a battery worth it?

A battery stores midday surplus for the evening, and can also charge from cheap off-peak grid power. Whether it pays back depends on the gap between your import and export prices, your evening use, and in Australia the federal discount.

HouseholdTypical evening/night useUseful battery size
1–2 people, gas heating3–5 kWh5 kWh
Family, gas heating6–9 kWh8–10 kWh
Family with heat pump or EV10–20 kWh10–15 kWh plus off-peak charging
All-electric, large home20 kWh+15–25 kWh, or two batteries

Batteries must be installed to the relevant fire-safety rules: in Australia AS/NZS 5139 restricts locations (not in habitable rooms, under stairs or in escape routes); in the UK, PAS 63100 (2024) gives installation guidance for home battery systems, including fire separation from escape routes; in the US, NFPA 855 and the IRC/IFC limit aggregate energy storage in garages and dwellings and require listing to UL 9540. See the lithium battery safety guide.

5. Backup in a power cut

Out of the box, most grid-tied systems, with or without a battery, shut down in a power cut. To keep running you need:

  1. An inverter with a backup (EPS/UPS) output or a separate backup gateway, which
  2. isolates your home or a backup circuit from the grid with an approved transfer relay or switch, then
  3. forms its own grid for the backed-up circuits from the battery and panels.
Backup typeWhat stays onSwitch-over
EPS socket on the inverterOne or two sockets you plug intoManual or a few seconds
Essential-loads circuitFridge, lights, router, boiler or furnace controlsAutomatic, under a second to a few seconds
Whole-home gatewayEverything, within the inverter's power limitAutomatic, usually seamless

Big loads (electric showers, ovens, heat pumps, central air) can exceed a home inverter's output; most installers put them outside the backup circuit or lock them out. For longer cuts, pair the battery with a generator; see the home backup power guide.

6. Getting paid for exports

UK: Smart Export Guarantee (SEG)

USA: net metering and net billing

Australia: feed-in tariffs

7. Time-of-use tariffs and load shifting

With import prices that change through the day, the cheapest strategy is often:

  1. Run dishwasher, washing machine, hot water and EV charging when the sun is out (or on the cheap overnight rate).
  2. Charge the battery overnight on a cheap rate in winter, when solar is low.
  3. Use the battery through the evening peak.
  4. Export at peak times if your export tariff pays more then.

A solar diverter sends surplus to an immersion heater instead of exporting it. It pays where export rates are low and you heat water electrically. Compare fuels with the heating fuel cost calculator.

8. Connection rules and standards by country

United Kingdom

United States

Australia

9. Plug-in (balcony) solar

From 27 August 2026, plug-in solar became legal to buy and connect yourself in Great Britain. Key points:

An 800 W kit typically saves £80–£150 a year if you use most of what it makes. In the USA, plug-in solar is not generally allowed under the NEC, though Utah passed a law in 2025 allowing small portable systems and other states are considering it. In Australia, plug-in solar connected through a power point is not permitted; all grid connection must be by a licensed electrician.

10. Incentives, grants and tax in 2026

CountrySchemeWhat it gives
UK0% VAT on energy-saving materialsSolar panels and batteries installed in homes are zero-rated until March 2027 (Great Britain); batteries retrofitted to existing solar also qualify
UKECO4 / Great British Insulation Scheme / local grantsFunded solar for some low-income or fuel-poor households; schemes change frequently
UK (Scotland)Home Energy Scotland loansInterest-free loans for solar and batteries
USAResidential Clean Energy Credit (25D)Ended: not allowed for installations completed after 31 December 2025
USAState and utility rebates, SRECs, property tax exemptionsVary widely; search DSIRE for your state
AustraliaSmall-scale Renewable Energy Scheme (STCs)Upfront discount on solar panels, declining each year until the scheme ends in 2030
AustraliaCheaper Home Batteries ProgramFrom 1 July 2025: about 30% off eligible batteries via STCs. From 1 May 2026, the discount is tiered by size (full rate to 14 kWh, 60% for 14–28 kWh, 15% for 28–50 kWh) and falls every six months
AustraliaState schemesFor example, interest-free loans and VPP incentives in some states

Incentives change often. Check the official scheme pages in the sources before you sign.

11. Getting quotes: what to ask

12. Monitoring and maintenance

13. Frequently asked questions

Will my solar panels work in a power cut?

Not unless the system has a backup output or gateway. Grid-tied inverters must shut down when the grid fails so they can't feed power into lines being repaired. A hybrid inverter with a battery and backup circuit, or a whole-home gateway, can keep chosen circuits running.

Do I need permission to connect solar panels to the grid in the UK?

Systems up to 16 A per phase (about 3.68 kW on a single-phase supply) can be connected under G98 and the DNO notified within 28 days. Larger systems, or solar plus a battery above that limit, need G99 approval from the DNO before connection.

Is plug-in solar legal in the UK?

Yes, in Great Britain from 27 August 2026, for approved kits up to 800 W AC that plug into a standard fixed socket. You must still notify your DNO under G98.

Is there still a federal solar tax credit in the US?

No. The Residential Clean Energy Credit (Section 25D) does not apply to systems whose installation was completed after 31 December 2025. State and utility incentives may still be available.

How much is the Australian battery rebate?

The federal Cheaper Home Batteries Program gives a discount through STCs on eligible batteries installed with solar. From 1 May 2026 it's tiered by battery size and falls every six months, so the dollar value depends on the battery size and installation date.

What size battery do I need with solar?

Enough to cover your typical evening and overnight use: often 5 kWh for a small household and 8–13 kWh for a family. Larger batteries make sense with an EV, a heat pump, frequent power cuts or time-of-use tariffs.

14. Sources

  1. GOV.UK, Smart Export Guarantee: gov.uk
  2. Energy Saving Trust, Smart Export Guarantee: energysavingtrust.org.uk
  3. Fuse Energy, plug-in solar legislation from 27 August 2026: fuseenergy.com
  4. Planning Portal, changes to permitted development for domestic solar (August 2026): planningportal.co.uk
  5. IRS, expiring clean energy tax incentives (25D and 25C): irs.gov bulletin
  6. California Public Utilities Commission, Net Billing Tariff: cpuc.ca.gov
  7. NYSERDA, the 120% rule fact sheet: nyserda.ny.gov
  8. Clean Energy Regulator, changes to the Cheaper Home Batteries Program: cer.gov.au
  9. CHOICE, solar home battery rebate changes: choice.com.au
  10. Standards Australia, what's new in AS/NZS 4777.1:2024: standards.org.au
  11. Energy Networks Australia, changes to inverter installation standards: energynetworks.com.au

New to some of the terms? See the glossary. Not sure where to start? Try start here.