The formulas
The 5.678 factor converts between W/m²·K and BTU/h·ft²·°F. A metric R-value is sometimes written RSI to make clear it isn't a US R-value.
Quick reference
| U-value (W/m²·K) | R-value (metric) | R-value (US) | U-factor (US) |
|---|---|---|---|
| 0.15 | 6.67 | R-37.9 | 0.026 |
| 0.18 | 5.56 | R-31.5 | 0.032 |
| 0.25 | 4.00 | R-22.7 | 0.044 |
| 0.30 | 3.33 | R-18.9 | 0.053 |
| 0.35 | 2.86 | R-16.2 | 0.062 |
| 0.50 | 2.00 | R-11.4 | 0.088 |
| 1.0 | 1.00 | R-5.7 | 0.176 |
| 1.4 | 0.71 | R-4.1 | 0.247 |
| 2.8 | 0.36 | R-2.0 | 0.493 |
| 5.7 | 0.18 | R-1.0 | 1.004 |
As a guide, single glazing is around 5.7 W/m²·K (U-factor about 1.0), modern double glazing 1.2–2.8, and well-insulated walls 0.18–0.35.
Which is better, high or low?
- U-value / U-factor: lower is better. It's the heat lost per square metre (or square foot) for each degree of temperature difference.
- R-value: higher is better. R-values of layers in a wall add together; U-values don't, so convert to R, add, then convert back.
To work out the R-value of a particular material and thickness, use the insulation R-value calculator; to see what it means for heater size, try the heat loss calculator.
Frequently asked questions
How do I convert a U-value to an R-value?
Divide 1 by the U-value. A U-value of 0.25 W/m²·K is an R-value of 4.0 m²·K/W. Multiply by 5.678 for the US R-value: R-22.7.
Is U-factor the same as U-value?
They measure the same thing. U-factor is the US term, in BTU/h·ft²·°F; U-value is usually metric, in W/m²·K. Divide a metric U-value by 5.678 to get the US U-factor.
What R-value is a U-value of 0.3?
R 3.33 m²·K/W metric, or about R-18.9 in US units.