Conversion factors
Common equipment
| Equipment | BTU/h | kW |
|---|---|---|
| 2 kW diesel air heater | 6,800 | 2.0 |
| 5 kW diesel air heater | 17,100 | 5.0 |
| RV roof air conditioner (cooling) | 13,500–15,000 | 4.0–4.4 |
| Portable propane heater (low–high) | 4,000–18,000 | 1.2–5.3 |
| Small wood stove | 15,000–35,000 | 4.4–10 |
BTU to watts chart
| BTU per hour | Watts | Kilowatts | Tons of cooling |
|---|---|---|---|
| 1,000 BTU/h | 293 W | 0.29 kW | 0.08 |
| 2,000 BTU/h | 586 W | 0.59 kW | 0.17 |
| 3,000 BTU/h | 879 W | 0.88 kW | 0.25 |
| 4,000 BTU/h | 1,172 W | 1.17 kW | 0.33 |
| 5,000 BTU/h | 1,465 W | 1.47 kW | 0.42 |
| 6,000 BTU/h | 1,758 W | 1.76 kW | 0.50 |
| 6,824 BTU/h | 2,000 W | 2.00 kW | 0.57 |
| 8,000 BTU/h | 2,345 W | 2.34 kW | 0.67 |
| 9,000 BTU/h | 2,638 W | 2.64 kW | 0.75 |
| 10,000 BTU/h | 2,931 W | 2.93 kW | 0.83 |
| 12,000 BTU/h | 3,517 W | 3.52 kW | 1.00 |
| 13,500 BTU/h | 3,956 W | 3.96 kW | 1.12 |
| 15,000 BTU/h | 4,396 W | 4.40 kW | 1.25 |
| 18,000 BTU/h | 5,275 W | 5.28 kW | 1.50 |
| 20,000 BTU/h | 5,861 W | 5.86 kW | 1.67 |
| 24,000 BTU/h | 7,034 W | 7.03 kW | 2.00 |
| 25,000 BTU/h | 7,327 W | 7.33 kW | 2.08 |
| 30,000 BTU/h | 8,792 W | 8.79 kW | 2.50 |
| 36,000 BTU/h | 10,551 W | 10.55 kW | 3.00 |
| 40,000 BTU/h | 11,723 W | 11.72 kW | 3.33 |
| 48,000 BTU/h | 14,067 W | 14.07 kW | 4.00 |
| 50,000 BTU/h | 14,654 W | 14.65 kW | 4.17 |
| 60,000 BTU/h | 17,584 W | 17.58 kW | 5.00 |
| 80,000 BTU/h | 23,446 W | 23.45 kW | 6.67 |
| 100,000 BTU/h | 29,307 W | 29.31 kW | 8.33 |
Watts to BTU chart
| Watts | Kilowatts | BTU per hour | kcal per hour |
|---|---|---|---|
| 100 W | 0.1 kW | 341 BTU/h | 86 kcal/h |
| 250 W | 0.25 kW | 853 BTU/h | 215 kcal/h |
| 500 W | 0.5 kW | 1,706 BTU/h | 430 kcal/h |
| 750 W | 0.75 kW | 2,559 BTU/h | 645 kcal/h |
| 1,000 W | 1 kW | 3,412 BTU/h | 860 kcal/h |
| 1,500 W | 1.5 kW | 5,118 BTU/h | 1,290 kcal/h |
| 2,000 W | 2 kW | 6,824 BTU/h | 1,720 kcal/h |
| 2,500 W | 2.5 kW | 8,530 BTU/h | 2,150 kcal/h |
| 3,000 W | 3 kW | 10,236 BTU/h | 2,580 kcal/h |
| 4,000 W | 4 kW | 13,649 BTU/h | 3,439 kcal/h |
| 5,000 W | 5 kW | 17,061 BTU/h | 4,299 kcal/h |
| 6,000 W | 6 kW | 20,473 BTU/h | 5,159 kcal/h |
| 8,000 W | 8 kW | 27,297 BTU/h | 6,879 kcal/h |
| 10,000 W | 10 kW | 34,121 BTU/h | 8,598 kcal/h |
| 12,000 W | 12 kW | 40,946 BTU/h | 10,318 kcal/h |
| 15,000 W | 15 kW | 51,182 BTU/h | 12,898 kcal/h |
| 20,000 W | 20 kW | 68,243 BTU/h | 17,197 kcal/h |
| 25,000 W | 25 kW | 85,304 BTU/h | 21,496 kcal/h |
| 30,000 W | 30 kW | 102,364 BTU/h | 25,795 kcal/h |
BTU, BTU/h and therms
- BTU is an amount of energy (1 BTU = 1,055 J = 0.000293 kWh). BTU/h is a rate of power. Heaters labelled "BTU" almost always mean BTU/h.
- A therm is 100,000 BTU, or 29.3 kWh. US gas bills use therms; UK bills use kWh.
- A ton of cooling is 12,000 BTU/h (3.517 kW), the rate of melting a ton of ice in 24 hours.
- Room heaters: allow roughly 20 BTU/h per square foot (about 60–100 W per m²) for a reasonably insulated room, more for old or draughty rooms. For a proper figure use the heat loss calculator.
Cooling BTU isn't electrical watts
An air conditioner rated at 13,500 BTU/h moves about 4 kW of heat, but it only draws about 1.2–1.6 kW of electricity, because air conditioners are heat pumps. For the electrical load, check the running watts on its label.
Frequently asked questions
How many watts is 5000 BTU?
5,000 BTU/h is about 1,465 W (1.47 kW) of heating or cooling output.
How many BTU is a 2kW heater?
About 6,824 BTU/h.
How many watts is 12,000 BTU?
About 3,517 W (3.5 kW). This is one ton of cooling. A 12,000 BTU air conditioner draws only about 1,000–1,300 W of electricity.
How many kW is 30,000 BTU?
About 8.8 kW.
How do I convert BTU to kWh?
Divide by 3,412. 100,000 BTU (one therm) is 29.3 kWh.