Home › Guides › Pellet stoves in power cuts

Pellet stoves and boilers in a power cut

Why pellet stoves need electricity, what happens in a power cut, power use, backup options, restarting safely, pellet boilers, storing pellets, and alternative heat.

By Michael Johnson · Updated 18 November 2026 · How we check our guides

Wood pellet stoves and boilers are popular in rural homes off the gas grid: they burn a renewable fuel cleanly, feed themselves automatically from a hopper, and can be controlled by a thermostat. But unlike a traditional log burner, a pellet appliance needs electricity to run its feed auger, fans, igniter and controls. In a power cut it stops heating, and in some cases smoke can leak into the room. This guide explains what happens to pellet stoves and boilers in a power cut, how to keep one running from batteries or a generator, restarting safely, and storing pellets so they stay usable.

Carbon monoxide: when the power fails, the exhaust fan stops while pellets are still smouldering. A properly installed stove with a correctly designed flue should vent naturally, but fit a CO alarm in the room and don't sleep in a room where smoke has leaked. If the alarm sounds, ventilate and get out.

1. Why pellet stoves need electricity

2. What happens in a power cut

3. How much power they use

StageTypical power
IgnitionAbout 300–500 W for 5–10 minutes
RunningAbout 50–150 W (larger ducted stoves more)
StandbyA few watts

Over a day, a stove running continuously at 100 W uses about 2.4 kWh, before ignition. Check the label or manual for your model.

4. Backup power options

OptionRuntimeNotes
UPS (500–1,000 VA, pure sine wave)20–60 minutesLets the stove shut down safely with fans running; won't heat for long
Portable power station (1–2 kWh)About 8–20 hours at 100 WPure sine wave output; check it can handle the igniter surge
Inverter and 12 V battery bankDepends on capacityBattery charger needed to recharge
GeneratorAs long as fuel lastsUse an inverter generator for clean power; outdoors only. See the generator guide

5. Restarting after a power cut

  1. Let the stove cool down fully.
  2. Empty unburnt pellets from the burn pot, so they don't cause a smoky or explosive restart.
  3. Clear any error messages following the manual.
  4. Check the flue and room for smoke smell; ventilate if needed.
  5. Restart with a normal ignition cycle.

6. Pellet boilers and central heating

7. Storing pellets

8. Alternative heat

9. Frequently asked questions

Will a pellet stove work in a power cut?

No. It needs electricity for the auger, fans and controls. It stops feeding pellets and the fire dies down.

Can I run a pellet stove on a power station?

Often yes, from a pure sine wave power station big enough for the igniter surge. At about 100 W running, a 1 kWh unit gives roughly 8 hours.

Why did my pellet stove smoke when the power went off?

The exhaust fan stopped while pellets were still burning. Check the flue design and door seals with your installer, and fit a CO alarm.

10. Sources

  1. Selectra, pellet stove electricity cost and power cuts: selectra.co.uk
  2. Anker SOLIX, how to power a pellet stove during an outage: ankersolix.com
  3. Harman PC45 manual, minimising smoke during loss of power: manualslib.com

New to some of the terms? See the glossary. Not sure where to start? Try start here.