Lead-acid battery care
Types of lead-acid battery, the golden rules, charging correctly, checking state of charge, topping up flooded batteries, equalising, sulphation, winter storage, terminals, and when a battery is finished.
By Michael Johnson · Updated 18 November 2026 · How we check our guides
Lithium batteries have taken over new off-grid systems, but millions of lead-acid batteries are still in use: leisure batteries in caravans and boats, flooded "traction" batteries in older off-grid homes, AGM and gel batteries in alarms, UPS units and backup systems, and the starter battery in every petrol and diesel car. Lead-acid batteries are tough and cheap, but they're unforgiving of neglect: leaving one partly discharged for weeks can permanently ruin it. This guide covers the types, charging correctly, topping up flooded cells, testing state of charge, equalising, avoiding sulphation, storage over winter, and safety.
1. Types of lead-acid battery
| Type | Maintenance | Notes |
|---|---|---|
| Flooded (wet), deep-cycle | Needs topping up with water | Long life if looked after; must be upright and ventilated |
| Sealed flooded ("maintenance-free") | No topping up | Common for cars and cheap leisure batteries |
| AGM (absorbed glass mat) | Sealed, no water | Spill-proof, handles higher charge and discharge currents |
| Gel | Sealed, no water | Good deep-cycle life, but needs lower charge voltages |
| Car starter battery | Usually sealed | Built for short high-current bursts, not deep discharge |
Compare them with lithium in the battery types compared guide.
2. The golden rules
- Recharge fully as soon as possible after use, every time.
- Don't discharge below about 50% regularly; deeper discharges shorten life sharply.
- Never leave it partly discharged for days or weeks.
- Use the correct charge voltages for the type (flooded, AGM, gel).
- Keep flooded cells topped up with distilled water, after charging.
- Keep it cool: heat speeds up ageing; cold reduces capacity.
3. Charging correctly
Lead-acid batteries charge in three stages: bulk (maximum current until the voltage rises), absorption (held at a set voltage while the current tapers) and float (a lower voltage to keep it full).
| Type (12 V) | Absorption | Float |
|---|---|---|
| Flooded | About 14.4–14.8 V | About 13.2–13.5 V |
| AGM | About 14.4–14.7 V | About 13.5–13.8 V |
| Gel | About 14.1–14.4 V | About 13.5–13.8 V |
Always check the battery maker's figures; they vary. Adjust for temperature: higher voltages in cold weather, lower in heat (a temperature sensor on the charger or controller does this automatically). Use the battery charging voltage calculator.
- A full recharge takes time: the absorption stage often needs several hours. Solar systems in winter often never complete it, which slowly sulphates the battery.
- Use a smart multi-stage charger or a solar charge controller set to the right battery type. See the charge controller guide.
4. Checking state of charge
| State of charge | Resting voltage (12 V) | Specific gravity (flooded) |
|---|---|---|
| 100% | About 12.7 V | About 1.265–1.280 |
| 75% | About 12.4 V | About 1.225 |
| 50% | About 12.2 V | About 1.190 |
| 25% | About 12.0 V | About 1.155 |
| Flat | 11.8 V or less | About 1.120 |
- Measure resting voltage after the battery has had no charge or load for several hours; voltage under load or charge is misleading.
- For flooded batteries, a hydrometer gives the most accurate reading of each cell. Measure after a full charge, not just after adding water. A difference of more than about 0.030 between cells suggests a weak cell or a need to equalise.
- A battery monitor with a shunt is the best way to track charge in daily use. See the battery monitoring guide and the battery voltage chart.
5. Topping up flooded batteries
- Check levels monthly at first, until you learn how quickly yours use water. Batteries in hot conditions or charged hard use more.
- Top up after a full charge, because the electrolyte expands while charging and can overflow.
- If the plates are exposed on a discharged battery, add just enough water to cover them, charge, then top up.
- Use only distilled or deionised water; tap water contains minerals that damage the plates. Never add acid.
- Fill to the level marked, usually just below the bottom of the filler neck. Don't overfill.
- Automatic watering systems save time on large banks.
6. Equalising
Equalising is a controlled overcharge, for flooded batteries only, that mixes the electrolyte and helps cells recover from mild sulphation and imbalance.
- Do it only when hydrometer readings are low or vary between cells after a full charge, or as the battery maker recommends (some recommend periodic equalising for solar systems).
- Typical equalise voltage for a 12 V flooded battery is about 16.2 V; check the maker's figure.
- Check water levels first, ventilate well, and disconnect sensitive 12 V equipment, which may not tolerate the high voltage.
- Check specific gravity regularly; stop when it stops rising.
- Never equalise sealed, AGM or gel batteries unless the maker specifically allows it.
7. Sulphation and how to avoid it
When a lead-acid battery discharges, lead sulphate forms on the plates. Normally it converts back when the battery is recharged. If the battery is left partly discharged, the sulphate hardens into crystals that won't convert back, permanently reducing capacity. This is the most common way lead-acid batteries die early.
- Recharge fully and promptly after every use.
- Keep stored batteries on a maintenance charger or float.
- Make sure solar systems are big enough to fully charge the battery regularly, or top up with a mains charger or generator in winter. See the winter solar guide.
- "Desulphating" chargers may help mildly sulphated batteries, but can't save badly sulphated ones.
8. Winter storage
- Fully charge before storage.
- Disconnect loads (alarms, trackers, clocks) that slowly drain it, or remove the battery.
- Keep it on a smart maintenance charger, or recharge every 4–8 weeks.
- A fully charged battery won't freeze in a British winter; a flat one can freeze at around −5 to −10 °C and crack.
- See the winterising guide.
9. Terminals and connections
- Clean corrosion with a solution of bicarbonate of soda and water, keeping it out of the cells, then rinse and dry.
- Clean posts and clamps until bright, refit, and apply a thin coat of terminal grease or petroleum jelly.
- Tighten to the specified torque. Loose connections cause heat and fires; overtightening can crack posts.
- Check connections between batteries in a bank; uneven cables cause uneven charging. See batteries in series and parallel.
10. When a battery is finished
- Signs: it won't hold charge, voltage drops fast under load, one cell reads much lower than the others, the case is bulging, or it gets hot when charging.
- Test capacity with a controlled discharge. See the battery capacity test calculator.
- Recycle old batteries: scrap yards, council tips and many garages accept them. Lead-acid batteries are hazardous waste and must not go in household bins.
- When replacing, consider whether lithium iron phosphate suits you better. See the lithium upgrade guide.
11. Frequently asked questions
How often should I top up a flooded battery?
Check monthly at first and top up after a full charge with distilled water. Once you know your usage, you can adjust the interval.
What voltage is a fully charged 12 V lead-acid battery?
About 12.7 V after resting several hours with no load or charging. 12.2 V is roughly half charged.
Should I equalise my AGM battery?
No, unless the manufacturer specifically allows it. Equalising is for flooded batteries.
Why did my leisure battery die after one winter?
Usually sulphation from being left partly discharged. Keep batteries fully charged or on a maintenance charger during storage.
12. Sources
- Trojan Battery, battery maintenance: trojanbattery.com
- Rolls Battery, 12 month maintenance schedule for flooded lead-acid batteries: rollsbattery.com
- PVEducation, special considerations for lead-acid batteries: pveducation.org
New to some of the terms? See the glossary. Not sure where to start? Try start here.