Home › Guides › Heat pumps in a power cut

Heat pumps in a power cut: backup power and frost protection

What happens in a power cut, how long the house stays warm, frost protection, how much power a heat pump needs, running it from a home battery or generator, hybrid systems, restarting, and a power cut plan.

By Michael Johnson · Updated 18 November 2026 · How we check our guides

A gas boiler stops in a power cut too, but a heat pump draws far more electricity, so it's much harder to keep going on backup. And if the power is off for a long time in freezing weather, an air source heat pump's outdoor pipework can freeze. With hundreds of thousands of UK homes now heated by heat pumps, this guide explains what happens in a power cut, how long the house stays warm, frost protection, running a heat pump from a home battery or generator, and a practical plan for keeping warm.

Size your backup: the heat pump backup power calculator works out the electrical draw, battery run time and inverter or generator size. The house cool-down calculator shows how long your home stays warm without heat.

1. What happens in a power cut

2. How long the house stays warm

HomeTime to fall from 20 °C to about 15 °C at 0 °C outside
Well-insulated new build or retrofitted homeAbout a day or more
Typical 1970s–2000s home with cavity and loft insulationAbout 6–12 hours
Older, draughty or solid-wall homeA few hours

Heat pump homes are usually better insulated, which helps. Check yours with the house cool-down calculator.

3. Frost protection: the real risk

When the power is on, heat pumps protect themselves: if the water gets cold, the circulation pump and compressor run to keep it above freezing. In a power cut, that protection stops.

In a long winter power cut, keeping the heat pump's circulation pump and controls powered (a few hundred watts) protects against freezing even if you can't run the compressor.

4. How much power a heat pump needs

Electrical draw ≈ heat output needed ÷ COP + pumps and controls
Heat pumpFull output draw at COP 2.5Typical draw on a cold day (70% load)
5 kWAbout 2.2 kWAbout 1.6 kW
7 kWAbout 3 kWAbout 2.1 kW
10 kWAbout 4.2 kWAbout 3 kW
Pumps and controls only (frost protection)About 100–200 W

5. Running it from a home battery

6. Running it from a generator

7. Hybrid systems and back-up heat

8. When the power comes back

9. A power cut plan for heat pump homes

10. Frequently asked questions

Do heat pumps work in a power cut?

No. They need electricity to run the compressor, fan and pumps. They usually restart automatically when power returns.

Can a heat pump freeze in a power cut?

A monobloc's outdoor pipes can freeze in a long cut in sub-zero weather if the system has no glycol or antifreeze valves. It's rare, but worth checking with your installer.

Can I run my heat pump on a generator?

Yes, through an electrician-fitted changeover switch, with a generator sized above the heat pump's full draw. An inverter generator gives cleaner power for the electronics.

How long will a home battery run a heat pump?

Typically 3–5 hours for a 7 kW heat pump on a cold day from a 10 kWh battery, if the battery's backup output is big enough. Running only the pumps for frost protection lasts much longer.

11. Sources

  1. UK Power Networks, power cuts, voltage issues and your low carbon technologies: ukpowernetworks.co.uk
  2. Renewable Heating Hub, heat pump freeze protection: are we overreacting?: renewableheatinghub.co.uk
  3. Altecnic, anti-freeze valves FAQs: altecnic.co.uk
  4. Heatable, will a home battery keep your lights on in a power cut?: heatable.co.uk
  5. OVO Energy forum, heat pump running from an electric generator: forum.ovoenergy.com
  6. WMCA, heat pump turns off: wmca.org.uk

New to some of the terms? See the glossary. Not sure where to start? Try start here.