Consumer units, RCDs and RCBOs explained
What is in a consumer unit, MCBs, RCDs and RCBOs, why it trips, finding the fault, testing RCDs, power cut or tripped switch, when to call an electrician, and backup power.
By Michael Johnson · Updated 18 November 2026 · How we check our guides
The consumer unit (fuse box) is where your home's electricity is split into circuits and protected. Knowing what's inside it, what an RCD, MCB and RCBO do, why one trips and how to find the cause safely saves a lot of worry in a power cut or when something keeps tripping. This guide explains the parts of a consumer unit, how to reset safely, testing RCDs, finding a fault that trips the power, when to call an electrician, and how backup power connects.
1. What's in a consumer unit
- Main switch: turns off the whole installation (but not the incoming cables).
- Circuit breakers: one for each circuit (lights, sockets, cooker, shower), labelled with their rating.
- RCDs or RCBOs: devices with a "T" or "Test" button that protect against electric shock.
- Older homes may have rewireable fuses and no RCD protection. Plug-in RCDs are a useful stop-gap.
2. MCBs, RCDs and RCBOs
| Device | Protects against | Trips when |
|---|---|---|
| MCB (miniature circuit breaker) | Overload and short circuit | Too much current flows: too many appliances, or a fault |
| RCD (residual current device) | Electric shock and some fires | Current leaks to earth (typically 30 mA for shock protection) |
| RCBO | Both, for one circuit | Either overload or earth leakage |
An RCD on its own doesn't protect against overload; it's paired with MCBs. With RCBOs, a fault only takes out one circuit, rather than half the house.
3. Why it trips
- Overload: kettle, heater and oven on one circuit together.
- Faulty appliance: a kettle, washing machine, immersion heater or outdoor light with a damaged element or water ingress.
- Damp: outdoor sockets, lights and garden equipment after rain.
- Damaged cable: a nail or screw through a cable.
- Nuisance tripping: many appliances each leaking a little to earth, all on one RCD.
4. Finding the fault
- Unplug everything on the affected circuits, and switch off fixed appliances such as the immersion heater.
- Reset the tripped device.
- If it stays on, plug appliances back in one at a time until it trips: that's the likely culprit.
- If it trips immediately with everything unplugged, the fault is probably in the fixed wiring or a fixed appliance. Leave it off and call an electrician.
- If an MCB trips repeatedly, don't hold it on or replace it with a bigger one.
5. Testing RCDs
- Press the test button on each RCD or RCBO. It should switch off immediately; then reset it.
- The IET recommends testing every six months, for example when the clocks change.
- If it doesn't trip when tested, get an electrician to check it.
- Test plug-in RCDs every time you use them.
6. Power cut or tripped switch?
- If neighbours' lights are off too, it's probably a power cut: call 105. See the 105 guide.
- If only your house is off and a switch is down, it's your installation.
- If nothing is tripped and neighbours have power, call 105 anyway: the fault may be in the supply to your home.
- Smart meters can tell you whether supply is reaching your meter.
7. When to call an electrician
- A device trips immediately with everything unplugged.
- Burning smells, scorch marks, buzzing or a hot consumer unit.
- No RCD protection, or rewireable fuses.
- Water has reached any electrics. See the electrics after a flood guide.
- Use a registered electrician (in England and Wales, one registered with a competent person scheme).
8. Backup power and the consumer unit
- Never back-feed a house through a socket from a generator or inverter.
- Connecting backup power needs a proper changeover switch or an essential-loads board. See the essential loads guide and the transfer switch guide.
- Battery and solar systems need correct RCD types; your installer will advise.
9. Frequently asked questions
Why does my RCD keep tripping?
Usually a faulty appliance, damp in outdoor electrics, or a cable fault. Unplug everything, reset, then reconnect items one at a time.
How often should I test my RCD?
The IET recommends pressing the test button every six months.
What is the difference between an RCD and an RCBO?
An RCD protects against earth leakage (electric shock). An RCBO combines that with overload protection for a single circuit.
10. Sources
- IET, consumer units and protective devices FAQs: theiet.org
- Electrical Safety First, RCDs explained: electricalsafetyfirst.org.uk
- IET, consumer guidance: consumer units: theiet.org
New to some of the terms? See the glossary. Not sure where to start? Try start here.