Home › Guides › Diesel heater

Diesel heaters: fitting, everyday use, fault-finding and repair

A practical owner's and workshop guide to air-type diesel parking heaters: 2, 5 and 8 kW budget units and the Eberspächer and Webasto designs they follow. It covers safety, how they work, fitting in vans, cabs, boats and outbuildings, tuning the hidden settings menu, maintenance, fault codes and electrical tests, a full tear-down and de-coke, alternative fuels and their tax rules in the UK, US and Australia, and water (coolant) heaters.

By Michael Johnson · Updated 16 November 2026 · How we check our guides

Covers: safe use and warnings · fitting · operation · vans, boats and outbuildings · tuning · maintenance · fault-finding · tear-down and repair · alternative fuels · water heaters

This guide is written for a competent DIY fitter or mechanic. It describes the common pattern of air heater: details such as fault-code numbers, connector layouts and torque figures vary between makes and even between batches of the same budget heater. Where a figure is given as 'typical', check it against the data plate and manual for your unit. Follow the heater maker's instructions where they differ from this guide.

1. Safety first: warnings that matter

A diesel heater is a small oil-fired furnace bolted into a vehicle. Fitted and used properly it is one of the safest ways to heat a van, cab, boat or workshop, because the flame and its exhaust are sealed away from the air you breathe. Almost every serious accident comes from one of the five hazards below.

1.1 Carbon monoxide and exhaust gas

DANGER Exhaust gas contains carbon monoxide (CO), which has no smell and can kill a sleeping person. The exhaust must discharge outside, every exhaust joint must be gas-tight, and combustion air must be drawn from outside, never from the living space.

1.2 Fire and heat

1.3 Fuel

DANGER Never put petrol, or diesel contaminated with petrol, in a diesel heater. Petrol vapour in a hot burner can ignite explosively. Petrol heaters exist, but they are different units with different parts.

1.4 Electrical

2. How the heater works

All air-type diesel heaters, from a premium Eberspächer Airtronic or Webasto Air Top to a budget unit, use the same layout. One electric motor drives two fans on a common shaft. A small blower feeds outside air to a burner, where a metered trickle of diesel is vaporised and burned inside a sealed aluminium heat exchanger. A larger fan blows cabin air over the outside of that heat exchanger and into the vehicle.

Cut-away of a diesel air heater showing the motor, combustion-air blower, glow plug, burner tube, heat exchanger, control board and the two separate air paths
Figure 1. Lengthways section through a typical air heater. Blue: cold air. Red: heated cabin air. Amber: fuel. Grey: exhaust gas.

2.1 The main parts

PartWhat it does
Dosing pumpA solenoid piston pump, mounted outside the heater. Each electrical pulse (a 'tick') delivers a fixed tiny shot of fuel. The control board sets heat output by changing the tick rate, roughly 1 to 6 ticks a second.
Glow plugA ceramic or sheathed-metal heating pin. It glows only during start-up to vaporise and light the fuel, and briefly at shut-down to burn the gauze clean. Once the flame is established it switches off.
Gauze / atomiser screenA fine stainless mesh sleeve around the glow plug. Fuel soaks into it and evaporates from its large surface area.
Burner (combustion tube)A perforated stainless tube where fuel vapour mixes with air and burns. Its small air holes are what carbon up when the heater runs cool and rich.
Heat exchangerA finned aluminium casting. Flame and exhaust stay on the inside; cabin air passes over the outside.
Motor and fansOne brushed or brushless DC motor: combustion-air blower on one end, heating-air fan on the other. A magnet and Hall sensor report fan speed to the control board.
Casing temperature sensorClipped to the heat exchanger. The board uses it to confirm the flame has lit (temperature rising), to detect flame-out (temperature falling) and to stop the heater on overheat.
Control board (ECU)Sits under the top cover. Sequences start and stop, modulates pump and fan, and stores fault codes.

2.2 Start, run and stop sequence

Timing chart of glow plug, fan speed and fuel pump through self-check, pre-heat, ignition, ramp-up, running and shut-down
Figure 2. What the glow plug, fan and fuel pump do through one heating cycle (bar height = relative level).

Understanding this sequence makes fault-finding much easier. During pre-heat the plug draws the heaviest current of the whole cycle, so weak wiring shows up here. During ignition the pump starts ticking slowly; you should see a little white vapour at the exhaust that clears within a minute or so as the flame takes hold. If the casing temperature has not risen after the allowed time, most heaters try once more and then lock out with an ignition-failure code. At shut-down the pump stops immediately and the fan runs on until the casing is cool.

2.3 Typical figures

2 kW class5 kW class'8 kW' budget class
Fuel use, low to highabout 0.10–0.25 L/habout 0.15–0.55 L/hsimilar to 5 kW in practice
Warm-air duct60 mm75 mm75–90 mm
Exhaust / combustion-air pipeabout 24 mm / 25 mmabout 24 mm / 25 mmabout 24 mm / 25 mm
Current at start (12 V)about 8–12 A for a minute or twoabout 8–12 Aabout 8–12 A
Current when running (12 V)about 0.7–2 Aabout 1–3.5 Aabout 1–4 A
Suitscar, small van, cabmedium or large van, small boatsee note below

NOTE A litre of diesel holds roughly 10 kWh of heat, so a true 8 kW heater would burn about 0.9 L/h flat out. Many budget heaters sold as 8 kW share the 5 kW casting, pump and burner, and deliver about the same heat. Buy on physical size and fuel consumption, not on the number in the listing. An oversized heater is a nuisance: it spends its life on its lowest setting, which is exactly what soots it up.

2.4 How heat output is controlled: the fuel and air map

The control board does not measure the flame directly. It simply pulses the pump at a chosen rate and spins the fan at the speed its stored settings say belongs with that rate. On budget heaters those settings are just two points, a minimum and a maximum, and the board draws a straight line between them. Every power level you select is a point somewhere on that line.

Graph of fan speed against dosing-pump rate showing the straight line between the minimum and maximum settings, with lean and rich zones
Figure 3. The fuel and air map of a typical 5 kW budget heater, using commonly reported default values.

This is why the same heater can burn cleanly or filthily depending on its settings, the fuel and the air density. If the fuel delivered per tick changes (a different pump, a thinner fuel) or the air gets thinner (altitude), the real mixture moves off the line even though the display shows the same numbers. Section 6 explains how to correct it.

2.5 Working out fuel use and heat from the pump rate

Each tick delivers a fixed volume, marked on the pump body: commonly 22 mL per 1,000 strokes on 5 kW budget heaters (smaller-output pumps exist for 2 kW units). So:

Fuel per hour (mL) = pump rate (Hz) × mL per stroke × 3,600

Diesel holds close to 10 kWh per litre. Not all of that reaches the cabin, because some leaves with the exhaust: a reasonable working figure is that about four-fifths becomes useful heat. One independent bench test of a 5 kW budget heater estimated about 3.6 kW delivered from 0.44 L/h at its maximum setting, and about 1.1 kW from 0.13 L/h at minimum.

Pump rateFuel per hourFuel in an 8-hour nightHeat in the fuelApprox. useful heat (80%)
1.2 Hz0.10 L0.8 L1.0 kW0.8 kW
1.6 Hz0.13 L1.0 L1.3 kW1.0 kW
2.0 Hz0.16 L1.3 L1.6 kW1.3 kW
2.5 Hz0.20 L1.6 L2.0 kW1.6 kW
3.0 Hz0.24 L1.9 L2.4 kW1.9 kW
4.0 Hz0.32 L2.5 L3.2 kW2.5 kW
5.0 Hz0.40 L3.2 L4.0 kW3.2 kW
5.5 Hz0.44 L3.5 L4.4 kW3.5 kW

NOTE The table assumes a 22 mL per 1,000 stroke pump that really delivers 22 mL. They do not all do so: the bench test mentioned above measured 26 mL per 1,000 strokes from a pump marked 22, which is 18% more fuel than the board believes it is supplying. Section 8.6 shows how to measure yours.

To work out running costs for your own heater, use the diesel heater fuel consumption calculator.

2.6 How the board knows there is a flame

3. Fitting the heater

Side view of a typical van installation: controller, battery and fuse, heater, warm-air duct, fuel tank, filter, dosing pump, intake and exhaust
Figure 4. Layout of a typical under-seat or floor-mounted installation.

3.1 Planning the position

3.2 Mounting plate and floor

  1. Mark out using the plate or the paper template: one opening (or three holes) for the stubs and four fixing holes.
  2. Cut the floor opening generously in any timber floor so that no wood sits near the exhaust stub. The steel plate bridges the opening.
  3. Treat cut metal edges with primer. Seal the plate to the floor with high-temperature sealant so that water, road spray and exhaust cannot enter.
  4. Fit the rubber base gasket between heater and plate, then tighten the four nuts evenly. This gasket is the seal between 'inside' and 'outside'.
Mounting plate seen from above with the four studs, combustion-air stub, exhaust stub and fuel inlet
Figure 5. Mounting plate and the three stubs that pass through it.

3.3 Exhaust and combustion air

Exhaust and combustion-air pipe routing under the floor, with silencer, drain hole, heat shield and outlet positions
Figure 6. Exhaust and combustion-air routing beneath the floor.
WARNING Never join or extend the exhaust inside the vehicle. Inside, the only exhaust component should be the stub passing straight through the mounting plate.

3.4 Fuel system

Fuel supply from tank through filter and dosing pump, pump outlet raised 15 to 35 degrees, and a correct butted pipe joint
Figure 7. Fuel supply layout and dosing-pump angle.

3.5 Warm-air ducting

3.6 Electrical connection

Block wiring diagram: battery, fuse and control board connected to the glow plug, fan motor, casing sensor, dosing pump and controller
Figure 8. Block wiring diagram. Connector styles and wire colours vary between makes.

3.7 Choosing the supply cable

Voltage lost in the cable is current × resistance, and the current has to travel out along the positive and back along the negative, so the length that matters is twice the run. For copper: volts lost ≈ 2 × run length (m) × amps × 0.0175 ÷ cable area (mm²). The table works this out for the 10 A or so a 12 V heater draws while the glow plug is on.

One-way run1.5 mm²2.5 mm²4 mm²6 mm²10 mm²
1 m0.23 V0.14 V0.09 V0.06 V0.04 V
2 m0.47 V0.28 V0.18 V0.12 V0.07 V
3 m0.70 V0.42 V0.26 V0.18 V0.11 V
4 m0.93 V0.56 V0.35 V0.23 V0.14 V
5 m1.17 V0.70 V0.44 V0.29 V0.18 V
7 m1.63 V0.98 V0.61 V0.41 V0.25 V

Volts lost at 10 A. Green: good. Amber: acceptable with a healthy battery. Red: expect low-voltage faults in cold weather. Fuse holders, crimp joints and connectors each add a little more, so aim for green.

For other currents and lengths, use the DC voltage drop calculator or the DC cable size calculator.

3.8 Designing the warm-air ducting

Good and poor warm-air duct layouts compared
Figure 9. Duct layout seen from above: what helps the heater breathe and what chokes it.

3.9 Fitting a standpipe to the vehicle tank

Standpipe fitted through a vehicle fuel tank sender flange, ending above the engine pickup
Figure 10. A heater standpipe fitted through the tank sender flange.
  1. Check first whether the sender unit already has a blanked auxiliary-heater take-off. Many vans do, and using it avoids drilling.
  2. Otherwise, run the tank low, disconnect the vehicle battery, clean the top of the tank thoroughly and remove the sender unit. Cover the tank opening while you work.
  3. On the bench, choose a flat area of the flange clear of the float arm and internal pipes. Drill to suit the standpipe's bulkhead fitting or grommet and deburr; wash away all swarf.
  4. Cut the standpipe so its end will sit above the engine's own pickup, leaving a reserve, and cut the tip at an angle so it cannot seal against the tank floor.
  5. Fit and seal the standpipe as its instructions describe, refit the sender with a new sealing ring if one is specified, and check for leaks with a full tank before refitting any trim.
DANGER Never drill a fuel tank in place, and never work on a petrol tank this way at all. Diesel vapour is hard to ignite but not impossible. If the sender cannot be removed for bench work, fit a separate heater tank instead.

4. Installation variants

Section 3 describes the classic under-seat fit in a van. The same heater ends up in boats, sheds, cabs and portable boxes, and each has its own traps.

4.1 Campervans and panel vans

4.2 Truck cabs and cars

4.3 Boats

Boat installation across the hull: heater on a rigid bracket, lagged exhaust with swan-neck to a skin fitting above the waterline
Figure 11. Typical boat installation, shown as a section across the hull.

A boat breaks the vehicle rule that the exhaust never runs inside: here it must cross a locker to reach the hull side. That makes the quality of the exhaust the most important part of the job.

4.4 Sheds, workshops and garages

Heater inside an outbuilding with exhaust and combustion air taken through the wall in a metal sleeve, and a battery on a float charger
Figure 12. Heater fitted inside an outbuilding, with exhaust and combustion air taken through the wall.

4.5 Portable all-in-one units

4.6 Heater mounted under the floor or outside

5. Commissioning and everyday use

5.1 First start

  1. Check: exhaust clamp tight, intake and exhaust ends clear, fuel in the tank, all fuel joints butted and clipped, fuse fitted, CO alarm working.
  2. Prime the fuel line. Most controllers have a priming mode that runs the pump alone (the key combination differs by controller, so see its leaflet). Run it until fuel, with only the odd small bubble, reaches the heater inlet, then stop. Do not over-prime: fuel pumped into a cold burner makes clouds of white smoke at start-up.
  3. Start the heater. Expect fan noise, then ticking from the pump, then a low roar. A puff of white smoke and a paint-curing smell on first use are normal.
  4. If it fails to light, let it finish its purge and try once more. After two failures, stop and find the cause (section 8) rather than keep flooding the burner.
  5. Run it on high for 20–30 minutes, then check every fuel joint for weeps and the exhaust joints for leaks (sooty streaks, or use a CO meter).

5.2 Good habits

5.3 Altitude

Thin air means less oxygen for the same fuel, so the mixture goes rich and the heater smokes and soots. As a rule of thumb, above about 1,500 m a standard heater should only be used briefly unless it is adjusted. Premium heaters offer altitude kits or automatic compensation. Many budget controllers have a hidden settings menu where pump rate can be reduced or fan speed increased: section 6 explains how to use it.

5.4 What the exhaust is telling you

What you seeLikely meaning
Nothing visible, faint hot shimmerNormal clean running.
Brief white vapour at start or stopNormal: unburnt fuel vapour before the flame is established or as it goes out.
Persistent white smoke, sharp smellFuel arriving but not burning: failed ignition, flooded burner, weak glow plug, blocked gauze, or water in fuel.
Grey or black smoke, sooty outletToo rich: restricted combustion air or exhaust, carboned burner, altitude, wrong fuel, or pump set too high.
Blue smokeOil-based fuel or additive being burned (see section 10).

5.5 Controller modes and why small vans overheat

5.6 Fuel and battery budgets

Fuel per night follows from the table in section 2.5. As a guide, a 5 kW heater ticking over uses around a litre in eight hours, and about three and a half litres flat out.

Running state (12 V)Typical currentUsed in 8 hoursUsed in 12 hours
Low outputabout 1.0 A8 Ah12 Ah
Medium outputabout 2.0 A16 Ah24 Ah
High outputabout 3.5 A28 Ah42 Ah
Each start (glow plug)about 10 A for 2–3 minutesabout 0.4–0.5 Ah per start
Each shut-down (fan run-on, plug re-fire)variesabout 0.2–0.4 Ah per stop

To size the battery for your own heating hours, try the battery run time calculator.

5.7 Cold-weather operation

6. Tuning and the hidden settings menu

Most budget controllers contain a password-protected engineering menu that sets the two ends of the fuel and air map described in section 2.4. Used carefully it cures smoke, soot and altitude problems. Used carelessly it overheats the heater or fills the burner with carbon. Premium heaters do not offer this: their maps are fixed and altitude is handled by a sensor or a dealer tool.

WARNING Write down every original value before you change anything, and change one value by a small step at a time. Never raise the maximum pump rate above the factory figure: that is the heater's overheat margin.

On the common blue-LCD controller, the engineering menu is reached from the settings screen by entering the code 1688. Other controllers use different key sequences, and some simple rotary or four-button controllers have no such menu at all. Aftermarket controllers expose the same values more conveniently.

6.2 What the settings mean

SettingWhat it doesCommonly reported values
Minimum pump rate (Hz)Fuel delivered at the lowest power level.About 1.3–1.6 Hz on 5 kW units; around 1.4 Hz on 2 kW units
Maximum pump rate (Hz)Fuel delivered at full power. Sets maximum heat and maximum casing temperature.About 5.0–5.5 Hz on 5 kW units
Minimum fan speed (rpm)Air supplied with the minimum pump rate.About 1,450–1,680 rpm
Maximum fan speed (rpm)Air supplied with the maximum pump rate.About 4,500 rpm
System voltage12 V or 24 V. Must match the heater hardware.As per data plate
Fan magnet setting (shown as SN-…)Tells the board how many pulses the fan sensor gives per revolution.Leave as supplied unless the motor has been changed
Glow plug type (shown as PF-…)Sets how hard the plug is driven.Leave as supplied unless the plug type has been changed

6.3 A safe tuning method

  1. Service the heater first. Tuning cannot fix a blocked gauze, an air leak in the fuel line or a restricted exhaust.
  2. Measure the pump's real delivery (section 8.6). If it over-delivers, that alone explains a rich burn.
  3. Run the heater at maximum for 15 minutes outdoors and watch the exhaust. Any visible smoke once fully warm means too rich. Reduce the maximum pump rate by 0.1–0.2 Hz, wait five minutes, and look again. Repeat until the exhaust is clear.
  4. Switch to minimum and wait ten minutes. If it smokes, smells or the flame hunts, raise the minimum fan speed by 50–100 rpm or reduce the minimum pump rate by 0.1 Hz.
  5. If the flame goes out at minimum, you have gone too lean or too low: restore the previous value.
  6. Return to maximum and confirm the heater does not trip on overheat with all ducts connected.
  7. Record the new values with the date and the fuel in use.

6.4 Altitude and fuel changes

6.5 Lowering the minimum for a small space

Reducing the minimum pump rate, with the minimum fan speed reduced in step, gives a gentler tick-over. There is a floor: below roughly 1.2 Hz most burners no longer stay hot enough to vaporise fuel cleanly, and the result is soot and flame-outs. If you run a lowered minimum, the habit of finishing each session on maximum becomes essential.

6.6 Symptoms of wrong engineering settings

SymptomSetting to check
Fan fault as soon as the motor starts, after a board or motor swapFan magnet setting does not match the motor
Voltage faults on a healthy supplySystem voltage set wrongly
Glow plugs failing every few weeks, or very slow ignitionGlow plug type setting does not match the plug fitted
Overheat trips at full power with clear ductsMaximum pump rate set too high, or pump over-delivering
Smoke only at the lowest settingMinimum fan speed too low for the minimum pump rate

7. Maintenance

These heaters need little attention if they are run hot and fed clean fuel. Neglected or run cold, they clog with carbon. The schedule below suits regular winter use; halve the intervals for full-time living aboard.

WhenJob
Every useGlance at the exhaust and intake ends. Listen for a steady pump tick and a smooth fan. Stop it from the controller.
Monthly, all yearRun for 10+ minutes, with the last few minutes on maximum. Test the CO alarm.
Start of each heating seasonCheck fuel pipe, joints and clips for cracks or weeping. Check exhaust and its clamps for corrosion, splits and soot streaks. Check intake pipe and silencer are clear (insects and mud). Clean battery and fuse connections. Vacuum dust from the return-air inlet and fan.
Yearly, or about every 500 running hoursRenew the in-line fuel filter. Drain water and sludge from a separate heater tank. Remove the glow plug, inspect it and clean or renew the gauze (section 9.1).
Every 2–3 years, or when starting gets slow or smokyFull strip and de-coke of burner and heat exchanger with new gaskets (section 9.2).
About 10 years (premium heaters)Makers such as Webasto specify renewing the heat exchanger at around ten years from first use, because of thermal fatigue.

7.1 Fuel care

7.2 Spares worth carrying

7.3 Laying up and recommissioning

Before a long lay-up:

Bringing it back into use:

8. Fault-finding and electrical tests

8.1 Fault codes: budget heaters

The table shows the numbering used by the common blue-LCD budget controllers. Numbering is not universal: other controllers and the premium makes use different lists, so confirm against the leaflet for your controller.

CodeUsual meaningFirst things to check
E-01Supply voltage too lowBattery charge; voltage at the heater plug during start; cable size; corroded fuse holder and joints.
E-02Supply voltage too highCharger or alternator over-voltage; 12 V unit on a 24 V supply.
E-03Glow plug faultPlug connector; plug open or short circuit (measure resistance); board driver.
E-04Fuel pump circuit faultPump plug and loom for breaks or shorts; pump coil.
E-05OverheatBlocked return-air inlet, crushed or closed ducts, too much duct, dust-choked fan; then the sensor itself.
E-06Fan motor faultFan jammed or rubbing; motor plug; Hall-sensor magnet missing or cracked; worn brushes or bearings.
E-07Communication faultController cable and plugs; damaged loom; remote-receiver fault.
E-08Flame-out while runningAir in fuel line, fuel starvation, waxed fuel, blocked filter, carboned burner, blocked exhaust, voltage sag.
E-09Temperature-sensor faultSensor plug loose; sensor open or short circuit.
E-10Failed to igniteNo fuel (prime it), weak glow plug, blocked gauze, low voltage, blocked exhaust or intake, water in fuel.

8.2 Step-by-step when it will not run

Fault-finding flowchart for a heater that will not run
Figure 13. Fault-finding order: electrics, then fuel, then ignition, then carbon.
  1. Display dead, or low-voltage code as soon as it tries to start? Measure voltage at the heater plug while the glow plug is on. A big drop from battery voltage means thin cable, a poor joint or a tired battery.
  2. Fan runs but the pump never ticks? Check the pump plug and loom for breaks or corrosion. Swap in a known-good pump if the coil reads open circuit.
  3. Pump ticks but no fuel reaches the heater? Prime the line. Look for air drawn in at joints, a blocked filter, a kinked pipe, an empty tank or a pickup above the fuel level.
  4. Fuel arrives, white smoke, no flame (ignition failure)? Test the glow plug. Pull the gauze and inspect it. Check exhaust and intake for blockage, water or a crushed pipe.
  5. Lights, runs, then goes out (flame-out)? Bubbles in the fuel line, waxed fuel, sagging voltage, coked burner or a restricted exhaust. Clean the burner if all else is good.

8.3 Simple bench tests

ComponentTestGood result (typical)
SupplyVoltmeter across the heater's main plug while the glow plug is heating.Within about 0.5 V of battery voltage; comfortably above 12 V on a 12 V system.
Glow plugUnplug it; measure resistance across its two wires, cold. Subtract the meter's own lead resistance.A low reading, typically from under 1 Ω to a couple of ohms for 12 V plugs and a few ohms for 24 V. Open circuit or dead short = scrap.
Dosing pumpUnplug from the loom and briefly pulse with the correct voltage: it should click sharply. Measure coil resistance.A clean click each pulse and a steady coil reading; open circuit = scrap. Pump output can be checked by collecting fuel over a counted number of ticks and comparing with the figure marked on the pump (commonly 22 mL per 1,000 strokes).
Temperature sensorMeasure resistance cold, then warm it in the hand.A stable reading that changes smoothly as it warms. Open circuit, short or jumpy = renew.
Fan motorSpin by hand with power off; then observe on start.Free and quiet, no rubbing. Speed should rise smoothly through the start sequence.
WARNING Do not test a glow plug by connecting it straight across a battery in free air for more than a second or two. Out of the heater it has nothing to carry the heat away, and ceramic plugs crack. Never touch it: it reaches red heat almost instantly.

8.4 Eberspächer / Espar Airtronic fault codes

Read out on the EasyStart controller, a diagnostic tool or the dealer software. A selection of the most useful codes for the Airtronic D2 and D4 family:

CodeMeaningNotes
010 / 011Over-voltage / under-voltage cut-offMust persist for about 20 seconds. Over-voltage is above about 16 V (12 V units) or 32 V (24 V units).
012 / 013Overheating at the overheat sensor / at the flame sensorCheck ducting and airflow first.
014Flame and overheat sensors disagree by too muchSensor position or sensor fault.
015 / 017Locked out after overheatingNeeds the fault memory cleared before it will run.
020 / 021Glow plug open circuit / short or overloadPlug should read about 0.6 Ω (12 V) or about 2 Ω (24 V).
031–034Blower motor open, shorted, or wrong speed033 means stuck, or more than 10% off its target speed for 30 seconds.
047 / 048Metering pump short circuit / open circuitPump coil should read about 9.5 Ω (12 V) or about 36 Ω (24 V).
050Too many failed starts: locked outFind the cause, then clear the fault memory.
051Flame detected at switch-onFlame sensor fault, or heater still hot.
052No flame within the safety timeFuel supply, glow plug, exhaust and intake.
053–056Flame went out at Power / High / Medium / Low stageFuel starvation, air in the line, carbon.
060–065Room sensor, control unit or flame sensor open or shorted
071 / 072Overheat sensor open / shorted
090–099Control box internal faults099 can be caused by supply voltage dipping very low.

NOTE Unlike budget heaters, an Eberspächer that has failed to start or has overheated several times in a row locks itself out on purpose. Repeatedly switching it on will not clear this: the stored faults have to be deleted with the controller's service function or a diagnostic tool.

8.5 Webasto Air Top 2000 STC fault codes

Shown on the timer display, or flashed on the control dial's lamp as a count of slow flashes after a burst of quick ones.

CodeMeaning
F00Control unit defective
F01No start
F02Flame failure
F03Supply voltage out of range
F04Flame detected before combustion
F05Flame sensor interrupted
F06Temperature sensor interrupted
F07Fuel pump interrupted
F08Combustion-air fan shorted or blocked
F09Glow plug circuit interrupted
F10Heater overheated
F11Overheat sensor interrupted
F12Heater locked out
F14Temperature rise too slow during start
F15Set-point potentiometer interrupted

8.6 Measuring what the dosing pump really delivers

Fuel-quantity test: pipe disconnected at the heater and led into a measuring cylinder while the pump runs
Figure 14. Fuel-quantity test. The pump stays where it is; only the heater end of the pipe is moved.
  1. Switch off and let the heater cool. Put rag under the heater's fuel inlet and pull the fuel pipe off its stub.
  2. Lead the pipe into a small measuring cylinder, or the barrel of a 10–20 mL syringe, held at about the height of the heater inlet.
  3. Run the controller's priming mode until fuel flows without bubbles, then empty the cylinder.
  4. Run priming again and count the ticks: 250 is a convenient number. Stop and read the volume.
  5. Divide the volume by the number of ticks and multiply by 1,000. Compare with the figure marked on the pump. (Example: 5.5 mL from 250 ticks = 22 mL per 1,000.)
  6. Refit the pipe, making sure it is pushed fully home, and wipe up.

8.7 Electrical test points

With the top cover off, each component plugs into the board separately, which makes testing straightforward. Connector shapes and wire colours differ between makes, so trace each lead to its component rather than relying on colour. Unplug before measuring resistance.

LeadHow to recognise itWhat to measureExpect
Main supplyTwo heavy wires from the loomDC volts at the board during pre-heatClose to battery voltage; see section 3.7
Glow plugTwo fairly heavy wires disappearing under a rubber cap on top of the castingResistance, coldLow: under 1 Ω up to a couple of ohms (12 V). Open circuit = failed
Fan motorLead entering the blower end of the heaterResistance across the motor wires; spin testA low, steady reading on brushed motors; a jumpy reading as you turn it suggests worn brushes
Fan speed sensorExtra thin wires in the motor lead, or a sensor on the board beside the fanDC volts on the signal wire while turning the fan slowly by handShould switch cleanly between high and low as the magnet passes
Casing sensorTwo thin wires to a tab clipped to the heat exchangerResistance cold, then warmedA steady value that moves smoothly with temperature (about 45–50 kΩ at 20 °C on the common NTC type)
Dosing pumpTwo wires leaving in the main loom to the pumpResistance at the pump plugA steady coil reading, typically from about ten to a few tens of ohms depending on make and voltage. Open circuit = failed
ControllerThree or four thin wires to the displaySupply volts at the controller plugSupply present; if so and the display is dead, suspect the controller

8.8 Control board faults

8.9 Symptom index

SymptomMost likely causes, in order
Nothing at all, display blankFuse; supply plug; controller cable; controller; board
Starts its fan, then stops with a voltage faultVoltage drop in the supply cable; weak battery; corroded fuse holder
No ticking from the pumpPump plug or loom; pump coil; board output
Ticks, white smoke, never lightsGlow plug; gauze; over-priming; water in fuel; blocked exhaust
Lights then dies after a minute or twoAir in the fuel line; sensor not seated; restricted fuel supply
Runs for an hour then flames outFuel waxing; tank vent blocked (vacuum in the tank); filter partly blocked; voltage sagging as the battery drains
Black smoke and sootBlocked intake or exhaust; carboned burner; pump over-delivering; altitude
Overheat tripsDucting too long or shut; return air blocked; dust on the fan; maximum pump rate too high
Surging or 'hunting' roarAir bubbles in the fuel; pump mounted flat or outlet-down; loose fuel joint
Loud ticking in the cabinPump bolted to a panel; soft wide-bore pipe; pipe touching bodywork
Whine or rattle from the heaterFan bearings; impeller rubbing; debris in the fan
Fuel smellWeeping joint; over-priming; fuel dripping from the exhaust after failed starts
Exhaust smell in warm airStop using it. Failed gasket, cracked heat exchanger, or exhaust drawn into the air inlet
Heater will not switch offNormal for several minutes: it is cooling down. If the fan never stops, suspect the casing sensor
Fuel dripping from exhaustRepeated failed starts have flooded the burner. Let it drain, find the ignition fault, expect heavy smoke on the next start

9. Tear-down and repair

9.1 Glow plug and gauze service (heater left in place)

Section through the glow-plug bore with gauze sleeve, and examples of clean, sooty and coked gauzes
Figure 15. Section through the glow-plug bore, and how to judge the gauze.
  1. Switch off at the controller, wait for the cool-down to finish, then pull the fuse.
  2. Release the top cover (clips or screws) and lift it off. Photograph the board and its plugs before disturbing anything.
  3. Unplug the glow-plug lead from the board and pull off the rubber cap or grommet over the plug.
  4. Unscrew the plug with the thin box spanner supplied with the heater. Work gently: ceramic plugs snap if levered sideways.
  5. Look down the bore with a torch. Hook the gauze out with a bent wire, a small pick or the tool supplied. Note which way up it sat; most have a slot or seam that lines up with the fuel inlet hole.
  6. Judge it against the gauze-condition drawing above (clean: refit; sooty: clean or renew; coked solid: renew). Light soot can be burned off with a blowlamp until the mesh glows clean, but gauzes are cheap and a new one is the better fix.
  7. Scrape loose carbon from the bore, and make sure the small fuel inlet hole in the side of the bore is open.
  8. Fit the gauze fully home, refit the plug finger-tight plus a light nip (it seals on a taper or washer and strips easily), reconnect, refit the cover and test.

9.2 Full tear-down and de-coke

Symptoms that call for a full strip: slow, smoky starts that a new plug and gauze did not cure; repeated flame-outs with good fuel and voltage; black smoke; or soot found in the exhaust stub. Buy a gasket set first. Old gaskets must not be reused, because they are what keeps exhaust gas out of your warm air.

Exploded view of a budget air heater with numbered parts 1 to 16
Figure 16. Exploded view along the centre line of a typical budget air heater.
No.PartNo.Part
1Inlet end cap / grille9Control board (ECU)
2Heating-air fan (impeller)10Glow plug
3Motor with combustion-air blower housing11Gauze / atomiser screen
4Blower-to-exchanger gasket12Casing temperature sensor
5Burner (combustion tube) on its flange13Upper shell
6Burner gasket14Lower shell
7Aluminium heat exchanger15Base gasket
8Outlet end cap / duct spigot16Steel mounting plate

Removal from the vehicle. Isolate the supply. Clamp or plug the fuel line and release it at the heater stub. Release the exhaust and intake clamps underneath, pull off the ducts, unplug the main loom, undo the four base nuts and lift the heater out. Work on a clean bench.

Strip-down order.

  1. Shells (13, 14). Unclip or unscrew the top cover and end caps (1, 8), then separate the two shell halves. Plastic clips are brittle when cold, so warm the case indoors first.
  2. Control board (9). Photograph, then unplug every connector: main loom, fan motor, glow plug, temperature sensor (the pump and controller usually join the main loom). Lift the board out and put it somewhere dry and static-safe.
  3. Sensor (12). Unclip or unscrew it from the heat exchanger. Note its exact position.
  4. Glow plug and gauze (10, 11). Remove as in section 9.1.
  5. Fan and blower assembly (2, 3). Undo the ring of screws (usually four) holding the blower housing to the heat exchanger. Draw the assembly straight off along the centre line and peel off gasket 4. Feed the motor lead and its grommet out carefully.
  6. Burner (5). Now visible inside the mouth of the exchanger, held by a few screws through its flange. These are often seized by heat: soak with penetrating oil, use a well-fitting bit and steady pressure. Withdraw the burner and peel off gasket 6.
  7. Heat exchanger (7). Nothing further to remove; it is one casting.

Cleaning.

Reassembly. Reverse the order with new gaskets 4, 6 and 15, dry, with no sealant on the hot joints. Tighten flange screws evenly and in a cross pattern; they thread into aluminium, so stop at firm. Make sure no wire is trapped between the shells or touching the heat exchanger. Refit to the vehicle, re-prime, and run on high for 20 minutes outdoors with the CO alarm beside the hot-air outlet before trusting it overnight. Expect a little smoke at first as cleaning residues burn away.

9.3 The burner in detail

Burner tube from the side showing small primary air holes, larger secondary holes and where carbon collects
Figure 17. Burner (combustion tube) seen from the side, removed from the heat exchanger.

9.4 Motor, blower and speed sensor

Section through the motor, heating-air fan and side-channel combustion blower with the Hall speed sensor
Figure 18. Section through the fan and blower assembly.

9.5 Differences on 2 kW units

Item2 kW class5 kW class
Body and ductingSmaller casting, 60 mm ductLarger casting, 75 mm duct
Burner and gasketsSmaller; not interchangeableLarger
Dosing pumpOften a smaller-delivery pump: check the markingCommonly 22 mL per 1,000 strokes
Glow plug and gauzeUsually the same type as the 5 kW from the same maker
Strip-downSame order. Fewer flange screws on some; access to the burner screws is tighterAs described in section 9.2
SettingsLower pump rates throughoutSee section 6.2

TIP When ordering spares for a budget heater, measure the old part and order by dimensions and photographs. Listings titled 'fits 2 kW / 5 kW / 8 kW' are frequently wrong for at least one of them.

9.6 Other common repairs

FaultRepair
Noisy or seized fanBearings are sometimes replaceable on brushless motors; on budget brushed motors a complete motor/blower assembly is the practical fix.
Pump ticks but delivers littleFlush with clean diesel; check the tiny inlet strainer some pumps have; otherwise renew. Do not dismantle the piston.
Loud pump tickRubber-mount the pump, use hard nylon pipe, and keep the pump off resonant panels.
Controller blankCheck fuse, then supply at the board plug, then the controller cable. Boards fail from over-voltage, reverse polarity and from power being cut while hot.
Heater overheats on long ductsShorten or enlarge the ducting, add a second outlet, clear the return-air path.
Diesel smell in the cabinWeeping fuel joint, or an exhaust leak drawn back in. Find it before using the heater again.

10. Alternative fuels

The heater is a vaporising burner tuned for road diesel (EN 590). It will burn other light distillates, but each one changes how cleanly it burns, how well the dosing pump is lubricated, and whether the maker (and your insurer) still stands behind it. The premium makers publish approved-fuel lists that differ by model, so check the manual for your exact heater. Budget heaters carry no meaningful approvals for anything but diesel.

FuelSuitabilityNotes
Road diesel (EN 590, up to 7% biodiesel)Designed for itUse winter grade in frost. Fresh fuel each season.
HVO / GTL paraffinic diesel (EN 15940)Very goodBurns cleaner with less soot and smell, stores far better than ordinary diesel and resists cold well. Approved by Webasto for its heaters; widely used in budget units without modification.
Kerosene / paraffin (28-second heating oil), Jet A-1Works; cleaner burn, with cautionsThinner, vaporises easily, soots much less and handles cold well. It lubricates the pump less than diesel, and it burns slightly differently, so some heaters run a little hotter or need the pump rate trimmed. Some premium models list kerosene as permitted; others do not. A diesel/kerosene blend is a common cold-weather compromise.
Red diesel / gas oil (35-second heating oil)Works; quality variesChemically close to road diesel. Off-road and heating grades can have higher sulphur and poorer cold performance, which shortens burner life.
Biodiesel blends above B7, B100 (FAME)Model-dependent; generally avoid in budget heatersThickens and gels in cold, absorbs water, ages quickly and can soften some rubber parts. A few premium models are approved for B100; most heaters are approved only for normal pump blends.
Vegetable oil, waste cooking oilNot recommendedFar too viscous for the dosing pump and gauze when cold; polymerises into hard varnish. Even small percentages blended into diesel coke the burner quickly.
Waste engine oil, hydraulic oil, ATFDo not useContains metals and additives that do not vaporise. They glaze the gauze and burner, and the exhaust is toxic. Sold-as-'waste oil' heater conversions need frequent strip-downs at best.
Petrol, or petrol/diesel mixesNEVERExplosion and fire risk in a diesel heater.
White spirit, thinners, alcohol, solventsNEVERWrong volatility and no lubrication; dangerous.

10.1 How the fuels compare

Typical published values. Individual batches vary, and cold-weather figures in particular depend on the season and the supplier.

PropertyRoad diesel (EN 590)HVO (EN 15940)Kerosene (heating grade)Biodiesel B100 (FAME)Vegetable oil
Density, kg per litre0.82–0.8450.77–0.790.78–0.81about 0.88about 0.92
Viscosity at 40 °C, mm²/s2.0–4.52.0–4.0about 1–23.5–5.0about 30–40
Flash pointabove 55 °Cabove 61 °C38 °C minimumabove 100 °Cabove 200 °C
Energy, kWh per litreabout 10.0about 9.5about 9.6about 9.2about 9.4
Cold limitFilter limit −5 °C summer, −15 °C winter (UK)Cloud point around −30 °C for good gradesStays fluid to around −40 °C or belowGels from about 0 to −10 °CThickens badly below about 10 °C
Storage lifeMonths; absorbs water, can grow sludgeYears; very stableYearsMonths; oxidisesPoor once exposed to air
Soot tendency in a heaterBaselineLowerLowerSimilar or higher when coldVery high

10.2 If you do change fuel

10.3 Tax and legality: United Kingdom

Kerosene and red diesel are rebated (lower-duty) fuels, and their permitted uses were tightened in April 2022. Heating is treated differently from propulsion, and the rules for a heater in a road vehicle, a boat or a building are not the same. HMRC guidance (Excise Notice 75) sets out the current position, so check it for your situation, keep rebated fuel in a separate, dedicated heater tank that cannot feed the engine, and keep receipts. This is general information, not legal advice.

10.4 Tax and legality: United States

The US federal system works on colour. Diesel and kerosene sold free of federal excise tax for off-road, farm and heating use are dyed red; clear fuel has had the tax paid (24.4 cents a US gallon on diesel). States add their own fuel taxes and rules on top, and these vary widely.

SituationFederal position in outline
Heater fed from the vehicle's own road-fuel tankThe fuel is ordinary taxed clear diesel. Nothing further to do. This is the simplest arrangement.
Dyed diesel or dyed kerosene in a separate heater tankHeating is a non-taxable use, so dyed fuel is the intended product. The tank must be completely separate and not connected to the tank that feeds the engine.
Dyed fuel in the propulsion tank of a registered highway vehicleProhibited, including when the vehicle is driven off-road. Any visible dye counts. The federal penalty is the greater of $1,000 or $10 per gallon, per violation, and states add their own.
Clear (taxed) kerosene burned for heat at homeA credit for the federal tax can be claimed on Form 4136 with the income tax return, if the kerosene was not bought from a 'blocked' untaxed pump.
Clear diesel or kerosene used by a business other than in a highway vehicle's engineA credit or refund may be available (Form 4136 annually, or Form 8849). Personal off-highway use does not generally qualify.
Untaxed clear kerosene from a 'blocked pump'Sold for non-highway use only. Higher-sulphur grades from such pumps may be restricted to heating use.

10.5 Tax and legality: Australia

Australia has no dyed, rebated fuel at the pump. Excise is charged on diesel, kerosene and heating oil alike (53.7 cents a litre from 3 August 2026, indexed twice a year), and relief is given afterwards through fuel tax credits to those who qualify.

SituationPosition in outline
Private user running a heater on pump dieselFull excise is paid in the pump price and there is nothing to claim. The non-business credit scheme covers generating electricity for domestic use and certain non-profit emergency vehicles, not heating.
Kerosene or heating oil bought for home heatingThe credit belongs to the supplier, who claims it and is expected to pass it on in the price. The householder does not claim. This does not extend to diesel sold for heating.
Kerosene in small retail containersThe packager can claim the credit on kerosene packed in containers of 20 litres or less for use other than in an engine, so the excise is normally already out of the shelf price.
GST-registered business using fuel for heatingCan generally claim fuel tax credits for taxable fuel used in carrying on the business, including diesel used for heating, on the business activity statement.
Light vehicles (4.5 tonnes GVM or less) on public roadsFuel used for travelling on public roads earns no credit. How fuel burned by a heater in such a vehicle is treated depends on the circumstances: ask the ATO or a tax agent before claiming.
Heavy vehicles on public roadsCredit is the excise less the road user charge for fuel used in travelling; fuel used by auxiliary equipment may be treated differently.

NOTE Sections 10.3 to 10.5 are a plain-language outline of the rules as published in late 2026. They are not legal or tax advice, the rules change, and penalties for getting it wrong can be heavy. Confirm your own position with the tax authority or an adviser.

TIP For most owners the best 'alternative' is HVO: it is a direct replacement, it keeps the burner noticeably cleaner, and it does not go off in the tank over summer. Its drawbacks are price and patchy availability.

11. Water (coolant) heaters

Everything so far concerns air heaters. The other family, sold as Eberspächer Hydronic, Webasto Thermo Top and budget copies, burns diesel in the same way but heats the engine's coolant instead of air. Many modern diesel cars and vans have one fitted at the factory as a supplementary heater.

Coolant heater circuit: engine, circulation pump, water heater and cab heater matrix
Figure 19. Basic coolant-heater circuit. Variations add a thermostat, non-return valves, radiators or a hot-water cylinder.

11.1 How they differ from air heaters

Air heaterWater heater
HeatsCabin air directlyEngine coolant, which then warms the cab matrix, the engine, radiators or a water cylinder
Extra partsNoneElectric circulation pump, coolant hoses, sometimes valves and a thermostat
Electrical loadLow once runningHigher: circulation pump plus the vehicle's own heater fan
Best forHeating a living space overnightPre-heating an engine, defrosting, hot water, or underfloor and radiator systems in larger conversions
Typical controlModulates continuouslyRuns high, drops to low, then pauses as coolant nears its upper limit and restarts as it cools (about 85 °C and 75 °C on one common model)

11.2 Installation points

11.3 Faults specific to water heaters

SymptomLikely cause
Overheat shut-down within a minute of lightingAir lock, low coolant, seized or disconnected circulation pump, closed heater valve
Runs but cab stays coldVehicle heater set to cold, matrix valve closed, coolant bypassing through the engine, vehicle fan not running
Short-cycles on and offCircuit volume too small or flow restricted; the coolant near the heater reaches its limit at once
Fails to light, then locks outAs for air heaters: fuel, glow plug, carbon. Typically a fault shut-down follows if no flame appears within about 90 seconds
Coolant lossHose clips, pump seal, or (rarely) a perforated heat exchanger

Burner servicing follows the same principles as an air heater, but these units are more compact and more model-specific. Get the workshop manual for the exact model before opening one, and fit new seals throughout.

12. Quick reference

12.1 Installation sign-off checklist

CheckDone
Heater on steel plate with base gasket; no timber near the exhaust stub; plate sealed to floor☐
Exhaust: short, falling, clamped, supported, drain hole at any low point, ends clear of body, no joints inside☐
Combustion air: drawn from outside, end away from exhaust and spray☐
Fuel: dedicated pickup, hard small-bore pipe, ends butted in joiners, clipped, clear of exhaust, pump outlet raised 15–35°☐
Ducting: one outlet cannot be closed; return-air inlet unobstructed☐
Electrical: fused at battery, adequate cable, crimped joints, no switch that can cut power when running☐
EN 50291-2 CO alarm fitted and tested; extinguisher to hand☐
Test run 20–30 minutes on high: no fuel weeps, no exhaust leaks, clean exhaust, normal shut-down☐
Insurer informed☐

12.2 Tools for servicing

Multimeter; glow-plug box spanner; cross-head and hex bits that fit well; penetrating oil; small picks and a bent wire; wire brush and small drill bits (hand-held) for burner holes; plastic scraper; vacuum cleaner; blowlamp; sharp blade for fuel pipe; torch; gasket set.

12.3 Glossary

TermMeaning
ADRThe international rules for carrying dangerous goods by road, which restrict heater fitting and use.
CFPPCold filter plugging point: the temperature at which wax blocks a standard test filter.
Cloud pointThe temperature at which wax crystals first appear in a fuel.
De-cokeRemoving carbon deposits from the burner and heat exchanger.
Dosing (metering) pumpThe solenoid pump that delivers a fixed shot of fuel per electrical pulse.
ECU / control boxThe heater's control board.
FAMEFatty acid methyl ester: conventional biodiesel.
Flame-outThe flame going out while the heater is running.
Gauze / atomiser screenThe mesh sleeve around the glow plug that wicks and vaporises fuel.
Hall sensorA magnetic sensor used to measure fan speed.
HVOHydrotreated vegetable oil: a paraffinic renewable diesel to EN 15940.
HzHertz: cycles per second. Here, pump ticks per second.
Lock-outThe heater refusing to start until stored faults are cleared.
NTCA temperature sensor whose resistance falls as it warms.
PrimingRunning the pump alone to fill the fuel line.
StandpipeA dedicated fuel pickup tube fitted into a tank.

12.4 Service log

Print this page or copy the table to keep a record of work done and settings used.

DateRunning hours (if known)Work done / parts fittedSettings (min/max Hz, min/max rpm)Fuel in use

12.5 Sources and further reading

  1. Eberspächer, Airtronic / Airtronic M technical description, installation, operation and maintenance instructions (altitude limits, installation rules): manualmachine.com
  2. Heatso, Eberspächer air heater installation checklist (exhaust length and routing): heatso.com
  3. Webasto, Air Top 2000 STC specification sheet (approved fuels, voltage range): PDF
  4. Webasto, Air Top Evo user manual (heat exchanger ten-year replacement): manuals.online
  5. Mellor support note on HVO / EN 15940 paraffinic fuel in Webasto heaters: melloronline.freshdesk.com
  6. Eberspächer UK motorhome heating brochure (biodiesel compatibility by model): PDF
  7. OnTrack Outdoor, 5 kW diesel heater fault table (E-01 to E-10): manuals.online
  8. Vevor diesel heater manual, fault display table: manualslib.com
  9. YBW forum, 'Kerosene in a diesel heater?' (user experience and maker comment on additives): forums.ybw.com
  10. Heatso, fault codes for Espar / Eberspächer D2 and D4 heaters (code list and test values): heatso.com
  11. CamperKing, Webasto Air Top 2000 STC fault code finder: guides.camperking.co.uk
  12. Pango, bench diagnostic protocol for a 5 kW Chinese diesel heater (settings, pump delivery, sensor type): PDF
  13. YBW forum, 'Chinese heater output control' (how the min/max settings interact): forums.ybw.com
  14. Nationwide Fuels, HVO fuel EN 15940 specification: nationwidefuels.co.uk
  15. IEA-AMF, properties of paraffinic fuels: iea-amf.org
  16. Eberspächer Hydronic technical descriptions (coolant requirements, control behaviour, fault shut-down): slideshare.net and scribd.com
  17. IRS Publication 510, Excise Taxes (including fuel tax credits and refunds): irs.gov
  18. IRS, Instructions for Form 4136, Credit for Federal Tax Paid on Fuels: irs.gov
  19. Mississippi Department of Agriculture and Commerce, dyed fuel questions and answers: PDF
  20. CPA Practice Advisor, 'IRS Issues FAQs on Tax Relief for Dyed Diesel Fuel Highway Use', 29 October 2026: cpapracticeadvisor.com
  21. ATO, Excise duty rates for fuel and petroleum products: ato.gov.au (search the title)
  22. ATO, Fuel sold for domestic home heating; Fuel tax credits, non-business eligibility; Packaging or supplying fuel: ato.gov.au (fuel schemes pages)
  23. HMRC Excise Notice 75: Fuels for use in vehicles (search gov.uk for the current edition).

NOTE Diagrams in this guide are simplified schematic drawings made for explanation. They are not to scale and do not reproduce any one manufacturer's unit.

General guidance only. Your heater maker's own instructions always take priority.

New to some of the terms? See the glossary. Not sure where to start? Try start here.